TrustCompo Website Logo | TrustCompo

KRPA-14AN-120 Power Relays, Over 2 Amps by TE Connectivity

KRPA-14AN-120 is a Power Relays, Over 2 Amps from TE Connectivity in manufacturer-listed packaging. It is commonly reviewed for RELAY GEN PURPOSE 3PDT 10A 120V. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.

Pictures are for reference only. Please contact us for the latest pictures.

KRPA-14AN-120 Power Relays, Over 2 Amps by TE Connectivity | TrustCompo
Pictures are for reference only. Please contact us for the latest pictures.
  • 365-Day GuaranteeAfter-sales support helps buyers handle quality questions with a clearer return and review window.
  • Ships within 24-48 HoursAvailable items can move quickly once the quote, quantity, and delivery details are confirmed.
  • 100% Anti-Counterfeit TestedParts are checked through authenticity-focused handling and inspection before shipment.

Key specifications

Part Number

KRPA-14AN-120

Internal code

TCE000087297

Package

-

Manufacturer
TE Connectivity

Key specifications

Series

KRPA

Min Quantity

1

Category
Relays
Description

RELAY GEN PURPOSE 3PDT 10A 120V

key Attributes

-

Trust signals

Quality and trust signals

Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.

4 certifications
  • ISO 9001

    Quality management processes for more consistent sourcing and handling.

  • AS9120B

    Aerospace-focused distribution controls for traceability and reliability.

  • ISO 14001

    Environmental management discipline across warehouse and operating workflows.

  • ESD Control

    Electrostatic handling standards to help protect sensitive components.

RFQ checklist

Order process

Confirm the core buying details for KRPA-14AN-120 before RFQ, PO release, and shipment planning.

  1. 1

    Confirm MPN

    Use the exact part number, manufacturer, package, and approval constraints in the RFQ.

  2. 2

    Check stock and price

    Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.

  3. 3

    Align documents

    Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.

  4. 4

    Arrange shipment

    Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.

Before PO release

Part confirmation

  • Exact MPN confirmed: KRPA-14AN-120
  • Package to verify: -

Commercial confirmation

  • Live stock and lead time confirmed by RFQ
  • Final price and tax terms confirmed before PO release

Fulfillment & documents

  • Ship-from location: Hong Kong warehouse
  • Shipping method: DHL, FedEx, UPS, or buyer forwarder account

Technical parameters

Parameters

Compare grouped KRPA-14AN-120 parameters from TE Connectivity, including package, series, key attributes, and technical values used for engineering and sourcing review.

  • Product Attribute

    Part Status

    Active

  • Product Attribute

    Manufacturer

    TE Connectivity

  • Product Attribute

    Packaging

    Tray

  • Product Attribute

    Factory Lead Time

    19 Weeks

  • Product Attribute

    Lifecycle Status

    ACTIVE (Last Updated: 1 day ago)

  • Product Attribute

    ELV Compliance

    Non-Compliant

KRPA-14AN-120 Product Attribute
ParameterValue
Part Status

Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.

Active
Manufacturer

Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.

TE Connectivity
Packaging

Indicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.

Tray
Factory Lead Time

Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.

19 Weeks
Lifecycle Status

Current stage in the product's lifecycle, such as Active, Obsolete, or End of Life. This indicates availability and long-term supply risk. Check this before designing in a part to ensure it will be available for your product's production lifetime.

ACTIVE (Last Updated: 1 day ago)
ELV Compliance

Indicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.

Non-Compliant
Approval Agency

Indicates the certification body that has tested and approved the component for safety or regulatory compliance. Buyers should verify this matches their target market requirements, and engineers should check the datasheet for the specific standards and marks.

CSA, UL
Published

Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.

2011
Insulation Resistance

Indicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.

1000000000Ohm
Current Rating

Specifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations.

10A
Relay Action

Specifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.

MOMENTARY
Dielectric Strength Between Open Contacts

Indicates the maximum voltage that can be applied across open contacts without causing an arc or breakdown. Critical for relay and switch isolation ratings. Verify against datasheet for safety margins in your application.

1000 Vrms
Coil Type

Specifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.

Non Latching
Sub-Categories

Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.

Power Relays, Over 2 Amps
Categories

Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.

Relays
Release Time

Release time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.

10 ms
Reference Standard

Indicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.

CSA; UL
Contact/Output Supply Type

Specifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.

AC
Relay Type

Classifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.

General Purpose
Dielectric Strength Between Coil And Contacts

This is the maximum voltage that can be applied between the relay coil and its contacts without causing insulation breakdown. It ensures safe isolation between control and switching circuits. Verify this rating against the datasheet for your application's voltage requirements.

1000 Vrms
Lead Free

Indicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.

Not Applicable
Number Of Pins

Total number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.

11
Termination

Describes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.

Plug
Mounting Type

Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.

Socket
Electrical Life

Number of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.

10000000 Cycle(s)
Coil Insulation

Insulation class or material used for the coil winding in relays, transformers, or solenoids. This determines the maximum operating temperature and dielectric strength. Choose a class that matches your thermal environment to prevent premature failure and ensure long-term reliability.

Class B
Mounting Type

Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.

Socketable
Switching Voltage

Specifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.

240VAC -Max
Voltage - Rated AC

Maximum AC voltage that the component can safely withstand under specified conditions. This rating is critical for insulation and safety margins. Always compare it with the operating voltage in your circuit and derate according to the datasheet guidelines.

240V
Contact Voltage Rating (AC)

Maximum AC voltage that the contacts can safely handle under normal operating conditions. Exceeding this rating can cause arcing or insulation breakdown. Verify that your application's AC voltage is within this limit to ensure reliable and safe operation of the connector or relay.

240V
Coil/Input Supply Type

Specifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.

AC
Additional Feature

Lists any extra characteristics or capabilities beyond the standard specifications, such as built-in protection, special mounting options, or enhanced performance. Review these features to ensure they meet your application's specific needs and compare them across similar parts.

COIL OPERATE VOLTAGE(AC): 102 V
Contact Material

Specifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.

Silver Cadmium Oxide (AgCdO)
Must Operate Voltage

Defines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.

102VAC
Coil Voltage

Specifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.

120VAC
Coil Voltage (AC)

AC voltage rating for the relay coil. Ensure the applied AC voltage matches this rating to avoid overheating or failure. Verify the frequency range and duty cycle in the datasheet.

120V
Max Voltage Rating (AC)

Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.

240V
Weight

Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.

84.708375g
Throw Configuration

Specifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.

3PDT
Contact Form

Specifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.

3PDT (3 Form C)
Width

Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.

35.687mm
Feature

This attribute highlights special characteristics or functions of the component, such as built-in protection, mounting style, or unique performance traits. Engineers compare these features to match specific application requirements. Always verify against the datasheet for complete specifications.

Lighted Indicator
Operating Temperature

Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.

-45°C~55°C
Length

Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.

35.7mm
Termination Style

Indicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.

Plug In, 11 Pin (Octal)
Height

Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.

50.8mm
Physical Dimension

Overall dimensions of the component, including length, width, and height. Essential for PCB layout and enclosure design. Confirm these measurements against the datasheet to ensure proper fit and clearance in your assembly.

48.8mm x 37.3mm x 34.9mm
Operate Time

Operate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.

15 ms
Series

Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.

KRPA
Coil Current

Specifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.

17.5mA
Coil Power

Power consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.

2.1W
Coil Resistance

Specifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.

2.25kOhm
Depth

Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.

37.3mm
Manufacturer'S Part No.

The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.

KRPA-14AN-120
KRPA-14AN-120 Export Classifications & Environmental
ParameterValue
RoHS Status

Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.

RoHS Compliant
REACH SVHC

Indicates whether the product contains substances of very high concern as per the REACH regulation. Buyers should verify this for compliance with EU environmental standards, especially when exporting to Europe. Check the manufacturer's declaration or datasheet for accurate SVHC status.

Unknown
ECCN Code

Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.

EAR99
Moisture Sensitivity Level (MSL)

Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.

Not Applicable
KRPA-14AN-120 Product Parameter
ParameterValue
Power Consumption

Typical power consumption of the component under normal operating conditions. This is important for power budget calculations and thermal management. Check the datasheet for maximum ratings and test conditions to ensure your design stays within safe limits.

2W

Datasheet preview

Datasheet PDF viewer

Preview the KRPA-14AN-120 datasheet from TE Connectivity to check package, electrical characteristics, application notes, and document evidence before RFQ.

TE Connectivity

KRPA-14AN-120

Page 1 of 0
/ —
Search within the PDF viewer.Try
Loading PDF viewer...

Notice documents

PCN / product notice documents

0 documents

No public PCN / PDN records currently displayed

No public product notice document is currently displayed for KRPA-14AN-120. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.

Common questions

Product FAQ

Targeted answers for buyers verifying the exact KRPA-14AN-120 ordering code, packaging, stock, datasheet, and replacement path.

What does KRPA-14AN-120 mean?

KRPA-14AN-120 is the exact ordering code listed for a Power Relays, Over 2 Amps component from TE Connectivity. The current package reference is -, with listed context including RELAY GEN PURPOSE 3PDT 10A 120V. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.

How should buyers verify the KRPA-14AN-120 ordering code?

Treat KRPA-14AN-120 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from TE Connectivity, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.

What package is KRPA-14AN-120 supplied in?

KRPA-14AN-120 is currently listed with package reference - from TE Connectivity. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.

Is KRPA-14AN-120 currently available?

KRPA-14AN-120 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (54098), available quantity (49754), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.

Where can I compare KRPA-14AN-120 alternatives?

A mapped alternative list is not currently published for KRPA-14AN-120. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.