1-1393243-3 Power Relays, Over 2 Amps by TE Connectivity
1-1393243-3 is a Power Relays, Over 2 Amps from TE Connectivity in DIP packaging. It is commonly reviewed for RELAY GEN PURPOSE DPDT 8A 60V. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.
Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.
4 certifications
ISO 9001
Quality management processes for more consistent sourcing and handling.
AS9120B
Aerospace-focused distribution controls for traceability and reliability.
ISO 14001
Environmental management discipline across warehouse and operating workflows.
ESD Control
Electrostatic handling standards to help protect sensitive components.
RFQ checklist
Order process
Confirm the core buying details for 1-1393243-3 before RFQ, PO release, and shipment planning.
1
Confirm MPN
Use the exact part number, manufacturer, package, and approval constraints in the RFQ.
2
Check stock and price
Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.
3
Align documents
Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.
4
Arrange shipment
Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.
Before PO release
Part confirmation
Exact MPN confirmed: 1-1393243-3
Package to verify: DIP
Commercial confirmation
Live stock and lead time confirmed by RFQ
Final price and tax terms confirmed before PO release
Fulfillment & documents
Ship-from location: Hong Kong warehouse
Shipping method: DHL, FedEx, UPS, or buyer forwarder account
Technical parameters
Parameters
Compare grouped 1-1393243-3 parameters from TE Connectivity, including package, series, key attributes, and technical values used for engineering and sourcing review.
Product Attribute
Part Status
Active
Product Attribute
Manufacturer
TE Connectivity
Product Attribute
Mounting Type
Through Hole
Product Attribute
ELV Compliance
Compliant
Product Attribute
Published
2008
Product Attribute
REACH Status
REACH Unaffected
1-1393243-3 Product Attribute
Parameter
Value
Part Status
Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
Manufacturer
Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
Mounting Type
Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Through Hole
ELV Compliance
Indicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.
Compliant
Published
Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2008
REACH Status
Shows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.
REACH Unaffected
ECCN
Export Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Lifecycle Status
Current stage in the product's lifecycle, such as Active, Obsolete, or End of Life. This indicates availability and long-term supply risk. Check this before designing in a part to ensure it will be available for your product's production lifetime.
ACTIVE (Last Updated: 1 day ago)
Packaging
Indicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.
Tube
Factory Lead Time
Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
4 Weeks
Operating Temperature
Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-40°C~85°C
Relay Action
Specifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.
MOMENTARY
Package / Case
Physical package or case type of the component, defining its dimensions, mounting style, and thermal characteristics. Common types include SMD, through-hole, BGA, and QFN. Choose the package that fits your PCB layout and assembly process. Verify the exact package code in the datasheet for footprint compatibility.
DIP
Coil/Input Supply Type
Specifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.
DC
Coil Type
Specifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.
Non Latching
Contact/Output Supply Type
Specifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.
AC/DC
Sub-Categories
Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Power Relays, Over 2 Amps
Seal Rating
Indicates the enclosure's protection level against gases, moisture, and contaminants. Compare ratings like IP or NEMA to ensure the component suits your operating environment. Verify the exact rating in the datasheet for reliable performance.
Sealed - Fully
Categories
Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Relays
Contact Form
Specifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.
DPDT (2 Form C)
Throw Configuration
Specifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.
DPDT
Contact Material
Specifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.
Silver Nickel (AgNi)
Coil Insulation
Insulation class or material used for the coil winding in relays, transformers, or solenoids. This determines the maximum operating temperature and dielectric strength. Choose a class that matches your thermal environment to prevent premature failure and ensure long-term reliability.
Class F
Switching Voltage
Specifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.
400VAC -Max
Weight
Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.
13g
Physical Dimension
Overall dimensions of the component, including length, width, and height. Essential for PCB layout and enclosure design. Confirm these measurements against the datasheet to ensure proper fit and clearance in your assembly.
29mm x 12.7mm x 15.7mm
Height
Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.
15.7mm
Reference Standard
Indicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.
BEAB; CSA; UL; VDE
Series
Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
RT2, SCHRACK
Electrical Life
Number of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.
30000 Cycle(s)
Radiation Hardening
Indicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet.
No
Number Of Pins
Total number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.
8
Termination Style
Indicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.
PC Pin
Relay Type
Classifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.
General Purpose
Packing Method
Specifies the packaging format for delivery, such as tube, reel, tray, or tape and reel. This affects handling, storage, and assembly processes. Verify the packing method against your production requirements and the datasheet to ensure compatibility with your pick-and-place equipment.
BULK
Width
Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.
12.7mm
Depth
Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.
12.7mm
Max Voltage Rating (AC)
Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.
400V
Sealing
Indicates the method used to protect the component from moisture, dust, and other environmental contaminants. Compare sealing types when operating conditions are harsh. Verify the specific sealing standard or rating in the datasheet to ensure reliability in your application.
RT3
Termination
Describes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.
Plug
Mounting Type
Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
Socket
Release Time
Release time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.
6ms
Length
Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.
29mm
Voltage - Rated AC
Maximum AC voltage that the component can safely withstand under specified conditions. This rating is critical for insulation and safety margins. Always compare it with the operating voltage in your circuit and derate according to the datasheet guidelines.
400V
Contact Voltage Rating (AC)
Maximum AC voltage that the contacts can safely handle under normal operating conditions. Exceeding this rating can cause arcing or insulation breakdown. Verify that your application's AC voltage is within this limit to ensure reliable and safe operation of the connector or relay.
250V
Operate Time
Operate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.
8ms
Contact Current Rating
Specifies the maximum continuous current each contact can safely carry. Compare this rating with your application's load requirements to prevent overheating or contact degradation. Always verify against the datasheet for derating curves and ambient temperature conditions.
8A
Coil Current
Specifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.
7mA
Coil Power
Power consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.
500mW
Coil Voltage (DC)
Specifies the nominal DC voltage required to energize the relay coil. Verify this matches your control circuit supply to ensure reliable switching. Check the datasheet for allowable tolerance and minimum pickup voltage.
60V
Manufacturer'S Part No.
The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
1-1393243-3
Must Operate Voltage
Defines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.
42VDC
Must Release Voltage
Specifies the voltage at which a relay is guaranteed to de-energize and return to its unoperated state. This value is critical for circuit design and ensuring reliable switching. Verify it against the datasheet to match your control signal and avoid unintended relay operation.
6VDC
Coil Resistance
Specifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.
8.57kOhm
Coil Voltage
Specifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.
60VDC
1-1393243-3 Product Parameter
Parameter
Value
Dropout Voltage
Dropout voltage is the minimum input-to-output differential required for a regulator to maintain regulation. Compare this value when selecting LDOs for battery-powered or low-headroom designs. Verify it against the datasheet to ensure your input supply stays above the dropout threshold under load.
Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
1 (Unlimited)
RoHS Status
Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
ROHS3 Compliant
HTSUS
Harmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.41.0020
ECCN Code
Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
Datasheet preview
Datasheet PDF viewer
Preview the 1-1393243-3 datasheet from TE Connectivity to check package, electrical characteristics, application notes, and document evidence before RFQ.
No public product notice document is currently displayed for 1-1393243-3. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.
Related sourcing options
Recommended products
Explore related Power Relays, Over 2 Amps products to compare fit, stock status, datasheets, and sourcing options.
Targeted answers for buyers verifying the exact 1-1393243-3 ordering code, packaging, stock, datasheet, and replacement path.
What does 1-1393243-3 mean?
1-1393243-3 is the exact ordering code listed for a Power Relays, Over 2 Amps component from TE Connectivity. The current package reference is DIP, with listed context including RELAY GEN PURPOSE DPDT 8A 60V. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.
How should buyers verify the 1-1393243-3 ordering code?
Treat 1-1393243-3 as the full ordering code during RFQ and engineering review. Confirm the listed DIP package, manufacturer documentation from TE Connectivity, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.
What package is 1-1393243-3 supplied in?
1-1393243-3 is currently listed with package reference DIP from TE Connectivity. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.
Is 1-1393243-3 currently available?
1-1393243-3 is currently marked with stock availability on this page. Before ordering, confirm the package (DIP), listed stock (132438), available quantity (86923), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.
Where can I compare 1-1393243-3 alternatives?
A mapped alternative list is not currently published for 1-1393243-3. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.