TrustCompo Website Logo | TrustCompo

17351251102 Backplane Connectors - Hard Metric, Standard by HARTING Technology Group

17351251102 is a Backplane Connectors - Hard Metric, Standard from HARTING Technology Group in manufacturer-listed packaging. It is commonly reviewed for CONN RECEPT 150POS 2MM PRESS-FIT. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.

Pictures are for reference only. Please contact us for the latest pictures.

17351251102 Backplane Connectors - Hard Metric, Standard by HARTING Technology Group | TrustCompo
Pictures are for reference only. Please contact us for the latest pictures.
  • 365-Day GuaranteeAfter-sales support helps buyers handle quality questions with a clearer return and review window.
  • Ships within 24-48 HoursAvailable items can move quickly once the quote, quantity, and delivery details are confirmed.
  • 100% Anti-Counterfeit TestedParts are checked through authenticity-focused handling and inspection before shipment.

Key specifications

Part Number

17351251102

Internal code

TCE000038564

Package

-

Key specifications

Series

har-bus® HM

Min Quantity

1

Description

CONN RECEPT 150POS 2MM PRESS-FIT

key Attributes

-

Trust signals

Quality and trust signals

Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.

4 certifications
  • ISO 9001

    Quality management processes for more consistent sourcing and handling.

  • AS9120B

    Aerospace-focused distribution controls for traceability and reliability.

  • ISO 14001

    Environmental management discipline across warehouse and operating workflows.

  • ESD Control

    Electrostatic handling standards to help protect sensitive components.

RFQ checklist

Order process

Confirm the core buying details for 17351251102 before RFQ, PO release, and shipment planning.

  1. 1

    Confirm MPN

    Use the exact part number, manufacturer, package, and approval constraints in the RFQ.

  2. 2

    Check stock and price

    Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.

  3. 3

    Align documents

    Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.

  4. 4

    Arrange shipment

    Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.

Before PO release

Part confirmation

  • Exact MPN confirmed: 17351251102
  • Package to verify: -

Commercial confirmation

  • Live stock and lead time confirmed by RFQ
  • Final price and tax terms confirmed before PO release

Fulfillment & documents

  • Ship-from location: Hong Kong warehouse
  • Shipping method: DHL, FedEx, UPS, or buyer forwarder account

Technical parameters

Parameters

Compare grouped 17351251102 parameters from HARTING Technology Group, including package, series, key attributes, and technical values used for engineering and sourcing review.

  • Product Attribute

    UL Flammability Code

    94V-0

  • Product Attribute

    Option

    GENERAL PURPOSE

  • Product Attribute

    Contact Style

    SQ PIN-SKT

  • Product Attribute

    Part Status

    Active

  • Product Attribute

    Filter Feature

    NO

  • Product Attribute

    Subcategory

    Headers and Edge Type Connectors

17351251102 Product Attribute
ParameterValue
UL Flammability Code

Specifies the UL flammability rating of the material used in the component, such as UL94 V-0 or HB. This is critical for safety in high-temperature or enclosed applications. Confirm the rating with the datasheet for your required safety standards.

94V-0
Option

Describes the specific configuration or variant of the component, such as packaging, lead form, or mounting style. Engineers compare options to match exact design requirements. Always check the option code against the datasheet to ensure compatibility with your application.

GENERAL PURPOSE
Contact Style

Specifies the physical shape or configuration of the electrical contact, such as pin, socket, blade, or crimp. This affects mating compatibility and reliability. Verify the contact style against the connector series and datasheet to ensure proper fit and performance in your application.

SQ PIN-SKT
Part Status

Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.

Active
Filter Feature

Specifies the type of filtering the component provides, such as EMI, RFI, or signal conditioning. Compare this attribute when selecting parts for noise suppression or signal integrity. Verify the exact filter topology and performance against the datasheet.

NO
Subcategory

A more specific classification within the main product category, such as 'Ceramic Capacitor' under 'Capacitors'. This helps narrow down search results and compare similar components. Use it to filter products with similar characteristics and intended applications.

Headers and Edge Type Connectors
Categories

Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.

Connectors, Interconnects
PCB Contact Pattern

Describes the arrangement and spacing of electrical contacts on the printed circuit board footprint. This attribute is critical for ensuring proper soldering and electrical connection. Verify against the recommended PCB layout in the datasheet to avoid assembly issues.

RECTANGULAR
Number Of Positions Loaded

Indicates how many contact positions in a connector housing are actually populated with contacts. Compare this to the total number of positions to understand which contacts are present. Verify against the datasheet or part marking to ensure the connector meets your wiring requirements.

All
Reliability

Reliability rating or qualification indicates the component's expected performance under specified conditions over time. Compare reliability levels when selecting parts for critical applications, and verify the qualification standard against the datasheet to ensure it meets your requirements.

COMMERCIAL
Number Of Conductors

Specifies how many separate conductive paths are inside the component, such as wires in a cable or traces in a connector. This affects current capacity and signal routing. Verify against the datasheet for proper circuit design and compatibility.

ONE
REACH Status

Shows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.

REACH Unaffected
ECCN

Export Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.

EAR99
Dielectric Withstanding Voltage

Specifies the maximum voltage that the insulation between conductors can withstand without breakdown. Critical for safety and reliability in power supplies, transformers, and connectors. Engineers must verify this rating against the datasheet for their application's isolation requirements.

750VAC V
Polarization Key

A physical feature on connectors or housings that ensures correct mating orientation. This prevents mismating and potential damage. Verify the key type and position against the datasheet to ensure compatibility with your mating connector and application.

POLARIZED HOUSING
Orientation

Indicates the physical mounting orientation of the connector relative to the PCB or mating direction. Engineers compare this to ensure proper alignment in the assembly. Verify against the datasheet for correct placement and mating.

Right Angle
HTS Code

Harmonized Tariff Schedule code used for customs classification of electronic components. Helps determine duties and regulatory requirements. Buyers should confirm the code with a customs broker for accurate shipping.

8536.69.40.40
Packaging

Indicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.

Tube
Mounting Type

Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.

Through Hole, Right Angle
Reference Standard

Indicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.

UL
Contact Resistance

Contact resistance measures the electrical resistance at the interface between mating contacts. Lower values indicate better conductivity and less heat generation. Compare this parameter across connectors, relays, and switches to ensure reliable signal integrity and power transfer. Always verify against the datasheet for your specific application.

20mOhm
Factory Lead Time

Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.

7 Weeks
Connector Type

Specifies the connector series or family, such as USB, RJ45, or D-Sub. This determines mechanical compatibility, pin layout, and mating standards. Verify against the datasheet to ensure the connector matches your board design and mating counterpart.

Receptacle, Female Sockets
Termination

Describes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.

Press-Fit
Durability

Indicates the number of mating cycles a connector can endure before electrical or mechanical failure. Compare this value when selecting connectors for frequent insertion and removal. Verify the rated cycles in the datasheet to ensure long-term reliability in your application.

500 Cycles
Withdrawal Force Min

Minimum force required to withdraw a connector from its mating part. Ensures reliable mechanical retention and prevents accidental disconnection. Engineers compare this for applications with vibration or shock. Check datasheet for test conditions.

.139 N
Operating Temperature

Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.

-55°C~125°C
Manufacturer

Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.

HARTING Technology Group
Insulation Resistance

Indicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.

10000000000Ohm
Length

Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.

49.9mm
Sub-Categories

Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.

Backplane Connectors - Hard Metric, Standard
Feature

This attribute highlights special characteristics or functions of the component, such as built-in protection, mounting style, or unique performance traits. Engineers compare these features to match specific application requirements. Always verify against the datasheet for complete specifications.

Upper Shield
Number Of Rows

Specifies how many rows of contacts the connector has, typically one, two, or more. This affects the connector's footprint, pin count, and mating force. Choose the row count based on your PCB layout and required pin density. Verify with the datasheet for exact row spacing.

5 + 1
Insulation Material

Specifies the dielectric material used to isolate conductive parts in components such as transformers, connectors, or cables. This affects thermal resistance, voltage withstand capability, and flammability rating. Verify the material against datasheet specifications for safety and performance in your application.

GLASS FILLED THERMOPLASTIC
Connector Style

Style or type of the connector, such as D-sub, USB, RJ45, or circular, determining its mechanical interface and electrical performance. Choose the style that matches your mating connector and application environment. Verify the connector style in the datasheet to ensure proper fit, pinout, and durability for your design.

AB 25
Pb-Free Code

Indicates whether the component is lead-free per RoHS or other directives. Buyers use this to verify environmental compliance and avoid restricted substances. Always confirm with the datasheet or certificate of compliance.

yes
DIN Conformance

Indicates whether the component complies with German DIN standards. Verify this attribute when the application requires specific mechanical, electrical, or safety specifications defined by DIN. Check the datasheet for the exact DIN number and edition to ensure compatibility with your system.

NO
Mixed Contacts

Indicates whether the connector combines different contact types, such as signal, power, or coaxial, in one housing. This attribute helps engineers identify versatile interconnect solutions for complex wiring systems. Verify the exact contact arrangement and ratings in the datasheet before design-in.

NO
MIL Conformance

Indicates whether the component meets military specifications (MIL-SPEC) for reliability, performance, and environmental resistance. This is critical for defense, aerospace, and high-reliability applications. Verify the specific MIL standard and test conditions in the datasheet.

NO
IEC Conformance

Indicates whether the component meets International Electrotechnical Commission standards. Check this attribute to ensure compatibility with international safety and performance requirements. Verify the specific IEC standard listed in the datasheet for your application.

NO
Contact Pattern

Describes the physical arrangement of contacts within the connector housing, such as rows and columns. This affects mating compatibility and PCB layout. Always check the pattern against your mating connector and board footprint to ensure proper alignment and avoid assembly issues.

RECTANGULAR
Mating Contact Row Spacing

This attribute specifies the center-to-center distance between rows of contacts in a mating connector. It is critical for ensuring mechanical compatibility with the corresponding receptacle and for PCB layout design. Engineers must verify this dimension against the connector's datasheet to avoid misalignment and ensure reliable connections.

0.079 inch
Number Of Columns

Specifies the count of contact columns in the connector grid. This affects the pin layout and mating compatibility. Verify against the datasheet to ensure the connector matches your PCB footprint and intended signal routing.

25
Body/Shell Style

Indicates the physical shape and configuration of the connector body or shell, such as circular, rectangular, or D-sub. This affects mounting, mating, and panel cutout requirements. Verify compatibility with your enclosure and mating connector before design-in.

PLUG
Pitch

The center-to-center distance between adjacent contacts in a connector. Pitch determines the connector's size and PCB footprint requirements. Smaller pitch allows higher density but may require more precise manufacturing. Verify pitch matches your board layout and mating connector to ensure reliable connections.

0.079 2.00mm
Number Of PCB Rows

Specifies how many parallel rows of pins or pads the component footprint occupies on the PCB. This affects board layout, routing, and mechanical fit. Verify against the recommended footprint in the datasheet to ensure proper mounting and soldering.

5
Contact Finish

Specifies the plating material on the contact surface, affecting conductivity, corrosion resistance, and durability. Compare finishes like gold, tin, or silver for mating cycle requirements and environmental exposure. Verify the exact finish and thickness in the datasheet to ensure reliable performance in your application.

Gold
Current Rating

Specifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations.

1A
Rated Current (Signal)

Maximum current rating for signal transmission through the component. This value ensures reliable signal integrity without overheating. Compare it with your circuit's actual signal current to avoid exceeding the limit, and verify derating factors for high-temperature environments.

1A
Mounting Option 1

Specifies the first available mounting method for the component, such as through-hole, surface mount, or panel mount. This determines the PCB layout and assembly process. Confirm that the chosen option matches your manufacturing capabilities and mechanical design requirements.

LOCKING
Total Number Of Contacts

Specifies the total number of electrical contact points in the connector. This determines the maximum number of circuits that can be connected. Verify against the datasheet to ensure it matches your required pin count and mating connector configuration.

125
Contact Material

Specifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.

NOT SPECIFIED
Max Current Rating

Specifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits.

1A
Series

Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.

har-bus® HM
Maximum Insertion Force

Maximum force needed to fully mate a connector pair. Critical for manual assembly ergonomics and automated production tooling. Verify against datasheet to ensure compatibility with your application's insertion equipment and operator comfort.

.139 N
Depth

Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.

23.75mm
PCB Contact Row Spacing

Specifies the center-to-center distance between parallel rows of contacts on the PCB footprint. This dimension is critical for ensuring proper alignment with mating connectors or sockets. Verify against the datasheet when designing the board layout or selecting a connector to avoid mechanical interference.

2 mm
Body Breadth

Measure the widest dimension of the component body, excluding leads and terminals. This attribute helps determine PCB footprint compatibility and mechanical fit. Verify against the datasheet drawing for accurate placement and clearance in your assembly.

0.543 inch
Additional Feature

Lists any extra characteristics or capabilities beyond the standard specifications, such as built-in protection, special mounting options, or enhanced performance. Review these features to ensure they meet your application's specific needs and compare them across similar parts.

SHIELDED, 1 SHIELDED ROW AVAILABLE AT PCB SIDE
Number Of Positions

Total number of contact positions in the connector. This determines the maximum number of electrical connections possible. Compare with your circuit requirements and verify against the datasheet to ensure the connector matches your pin count and layout.

150 (125 + 25 Ground)
Manufacturer'S Part No.

The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.

17351251102
17351251102 Export Classifications & Environmental
ParameterValue
Moisture Sensitivity Level (MSL)

Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.

1 (Unlimited)
HTSUS

Harmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.

8536.69.4040
RoHS Status

Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.

ROHS3 Compliant
JESD-609 Code

This code indicates the terminal finish material per JESD-609 standard. It helps identify the plating type for soldering compatibility and environmental compliance. Check the datasheet for the exact code and its meaning.

e4
ECCN Code

Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.

EAR99

Datasheet preview

Datasheet PDF viewer

Preview the 17351251102 datasheet from HARTING Technology Group to check package, electrical characteristics, application notes, and document evidence before RFQ.

HARTING Technology Group

17351251102

Page 1 of 0
/ —
Search within the PDF viewer.Try
Loading PDF viewer...

Notice documents

PCN / product notice documents

0 documents

No public PCN / PDN records currently displayed

No public product notice document is currently displayed for 17351251102. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.

Common questions

Product FAQ

Targeted answers for buyers verifying the exact 17351251102 ordering code, packaging, stock, datasheet, and replacement path.

What does 17351251102 mean?

17351251102 is the exact ordering code listed for a Backplane Connectors - Hard Metric, Standard component from HARTING Technology Group. The current package reference is -, with listed context including CONN RECEPT 150POS 2MM PRESS-FIT. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.

How should buyers verify the 17351251102 ordering code?

Treat 17351251102 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from HARTING Technology Group, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.

What package is 17351251102 supplied in?

17351251102 is currently listed with package reference - from HARTING Technology Group. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.

Is 17351251102 currently available?

17351251102 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (59122), available quantity (77958), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.

Where can I compare 17351251102 alternatives?

A mapped alternative list is not currently published for 17351251102. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.