ECE20US05 is a DC DC Converters from XP Power in DIP packaging. It is commonly reviewed for AC/DC CONVERTER 5V 20W. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.
Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.
4 certifications
ISO 9001
Quality management processes for more consistent sourcing and handling.
AS9120B
Aerospace-focused distribution controls for traceability and reliability.
ISO 14001
Environmental management discipline across warehouse and operating workflows.
ESD Control
Electrostatic handling standards to help protect sensitive components.
RFQ checklist
Order process
Confirm the core buying details for ECE20US05 before RFQ, PO release, and shipment planning.
1
Confirm MPN
Use the exact part number, manufacturer, package, and approval constraints in the RFQ.
2
Check stock and price
Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.
3
Align documents
Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.
4
Arrange shipment
Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.
Before PO release
Part confirmation
Exact MPN confirmed: ECE20US05
Package to verify: DIP
Commercial confirmation
Live stock and lead time confirmed by RFQ
Final price and tax terms confirmed before PO release
Fulfillment & documents
Ship-from location: Hong Kong warehouse
Shipping method: DHL, FedEx, UPS, or buyer forwarder account
Technical parameters
Parameters
Compare grouped ECE20US05 parameters from XP Power, including package, series, key attributes, and technical values used for engineering and sourcing review.
Export Classifications & Environmental
Moisture Sensitivity Level (MSL)
1 (Unlimited)
Export Classifications & Environmental
RoHS Status
ROHS3 Compliant
Export Classifications & Environmental
ECCN Code
EAR99
Export Classifications & Environmental
JESD-30 Code
R-XDMA-P4
Export Classifications & Environmental
HTSUS
8504.40.6001
Product Parameter
Min Input Voltage (AC)
85V
ECE20US05 Export Classifications & Environmental
Parameter
Value
Moisture Sensitivity Level (MSL)
Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
1 (Unlimited)
REACH SVHC
Indicates whether the product contains substances of very high concern as per the REACH regulation. Buyers should verify this for compliance with EU environmental standards, especially when exporting to Europe. Check the manufacturer's declaration or datasheet for accurate SVHC status.
Unknown
RoHS Status
Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
ROHS3 Compliant
ECCN Code
Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
JESD-30 Code
JEDEC standard code that defines the package outline and dimensions. Use it to verify physical compatibility and footprint before PCB design. Compare with the datasheet to ensure the component meets your assembly and manufacturing requirements.
R-XDMA-P4
HTSUS
Harmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8504.40.6001
ECE20US05 Product Parameter
Parameter
Value
Min Input Voltage (AC)
Specifies the lowest alternating current voltage at which the component reliably operates. Compare this value with your power supply's output to ensure proper startup and stable performance. Always verify against the datasheet for your specific application conditions.
85V
Nominal Output Voltage
Specifies the designed output voltage level under standard operating conditions. Compare this value with your circuit requirements and verify against the datasheet's tolerance and load regulation to ensure compatibility with your application.
5V
Max Output Power
Maximum power the device can deliver at the output under specified conditions. Compare this rating with your application's load requirements to ensure sufficient headroom. Verify against the datasheet's test conditions, as output power may vary with input voltage, temperature, and load impedance.
20W
Nominal Input Voltage
Specifies the typical input voltage level for which the component is designed to operate. Compare this value with your power supply output to ensure compatibility. Always verify against the datasheet for absolute maximum ratings and operating conditions.
115V
Max Input Voltage (AC)
Specifies the highest alternating current voltage that can be safely applied to the input terminals. Exceeding this limit may damage the component. Verify this value against the datasheet for your specific application to ensure reliable operation.
264V
ECE20US05 Product Attribute
Parameter
Value
Part Status
Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
Mounting Type
Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Through Hole
ECCN
Export Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Factory Lead Time
Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
25 Weeks
Published
Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2011
Terminal Position
Position of the terminals on the package, such as dual-in-line, gull-wing, or J-lead. This affects PCB layout, soldering, and thermal performance. Engineers must ensure the terminal position matches the footprint and assembly capabilities of their manufacturing line.
DUAL
Qualification Status
Shows if the component meets a specific industry standard or reliability level. Buyers should verify this against the datasheet to ensure the part is suitable for their application's environmental and performance requirements.
Not Qualified
Technology
Manufacturing technology or process used for the component, such as thin film, thick film, or semiconductor process. Affects performance, stability, and cost. Confirm the technology matches your application requirements and environmental conditions.
HYBRID
Min Input Voltage
Minimum voltage required at the input for the component to operate correctly. Below this level, the device may not function or may produce incorrect outputs. Verify that your power supply provides at least this voltage under all load conditions.
85V
Categories
Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Power Supplies - Board Mount
Applications
Specify the typical end-use scenarios for this electronic component, such as consumer electronics, automotive, industrial, or telecommunications. This helps engineers quickly assess suitability for their design. Verify against the datasheet's application section.
ITE (Commercial)
Max Power Dissipation
Maximum power the component can safely dissipate as heat without damage. Exceeding this may cause failure. Check datasheet for thermal resistance and derating curves under your operating conditions.
20W
Number Of Functions
Specifies the count of independent functions or channels integrated into a single component package. This helps engineers determine if the part can handle multiple signal paths or operations simultaneously. Verify against the datasheet to ensure the device meets your circuit's functional requirements.
1
Mounting Type
Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
Through Hole
Number Of Outputs
Specifies how many independent output channels the component provides. Compare this when selecting power supplies, drivers, or modules to ensure the device can drive all required loads. Always verify against the datasheet for exact output configuration.
1
Number Of Terminations
Indicates the total number of electrical connection points on the component, such as pins or pads. This is critical for PCB footprint design and assembly. Verify it matches the package specification to ensure proper soldering and connectivity.
4
Trim/Adjustable Output
Indicates whether the output voltage or current can be trimmed or adjusted externally. Useful for power modules and regulators where fine-tuning is needed. Check the datasheet for trim range and method.
NO
Efficiency
Efficiency indicates how effectively a power component converts input power into useful output power, expressed as a percentage. Higher efficiency means less energy lost as heat, which is critical for thermal management and system reliability. Always verify the efficiency curve in the datasheet under your operating conditions.
77%
Output Voltage
Specifies the regulated voltage level available at the output pin under specified load and input conditions. Compare this value with your circuit requirements and verify against the datasheet's tolerance and temperature derating.
5V
Output Power
Specifies the maximum power the component can deliver to the load under rated conditions. Compare this value with your application's power requirement to ensure sufficient headroom. Verify against the datasheet's derating curves and thermal limits for reliable operation.
20W
Output Current
Current supplied at the output, indicating the load-driving capability of the component. This is crucial for ensuring the component can drive downstream circuitry without overheating or voltage drop. Compare with your load requirements and check the datasheet for maximum ratings.
4A
Power Rating
Specifies the maximum power the component can safely dissipate under defined operating conditions. Compare this value with your circuit's power requirements to prevent overheating and ensure reliable operation. Always verify against the datasheet for derating curves and ambient temperature limits.
20W
Max Input Voltage
Maximum voltage that can be applied to the input without causing damage or malfunction. Exceeding this limit may lead to breakdown or reduced reliability. Always compare with your supply voltage and check the datasheet for absolute maximum ratings.
264V
Subcategory
A more specific classification within the main product category, such as 'Ceramic Capacitor' under 'Capacitors'. This helps narrow down search results and compare similar components. Use it to filter products with similar characteristics and intended applications.
Power Supply Modules
Terminal Form
Describes the physical configuration of the component's leads or pads, such as through-hole, surface mount, or gull-wing. This affects PCB layout, soldering process, and mechanical fit. Confirm compatibility with your assembly method and footprint.
PIN/PEG
Width
Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.
27.2mm
Max Output Current
Specifies the highest continuous current the device can supply at its output without exceeding thermal or electrical limits. Compare this value with your load requirements and derating curves. Always verify against the datasheet for your operating conditions.
4A
Height
Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.
23mm
Output Current 1
Specifies the maximum continuous current available at the first output of a power supply or converter. Compare this value with your load requirements to ensure sufficient headroom. Verify against the datasheet's derating curves and operating conditions.
4A
Package / Case
Physical package or case type of the component, defining its dimensions, mounting style, and thermal characteristics. Common types include SMD, through-hole, BGA, and QFN. Choose the package that fits your PCB layout and assembly process. Verify the exact package code in the datasheet for footprint compatibility.
4-DIP Module
Depth
Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.
52.4mm
Line Regulation
Measures how much the output voltage changes when the input voltage varies. Lower values indicate better stability. Critical for power supplies and regulators. Check datasheet for specified input range and load conditions.
±0.5%
Sub-Categories
Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
AC DC Converters
Size / Dimension
Physical dimensions of the component, typically length, width, and height. These measurements are critical for PCB layout and mechanical fit. Always verify against the datasheet for exact tolerances and mounting requirements.
2.06Lx1.07W x 0.91 H 52.3mmx27.2mmx23.0mm
Load Regulation
Indicates how much the output voltage changes when the load current varies. Better load regulation means a more stable output. Check the datasheet for the specified load range and conditions to ensure your application's voltage tolerance is met.
±1%
Protections
Indicates built-in safety features such as overcurrent, overvoltage, thermal shutdown, or short-circuit protection. Compare these capabilities when selecting components for reliable operation. Always verify the specific protection thresholds and behavior in the datasheet.
OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
Type
Select the component category that best matches your application, such as resistor, capacitor, diode, or connector. This classification helps narrow down the correct part family and ensures compatibility with your circuit design. Verify the type against the datasheet to avoid mismatches.
Enclosed
Manufacturer
Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
XP Power
Weight
Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.
0.132lb 59.87g
Feature
This attribute highlights special characteristics or functions of the component, such as built-in protection, mounting style, or unique performance traits. Engineers compare these features to match specific application requirements. Always verify against the datasheet for complete specifications.
OVP, SCP
Operating Temperature
Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-25°C~70°C With Derating
Approval Agency
Indicates the certification body that has tested and approved the component for safety or regulatory compliance. Buyers should verify this matches their target market requirements, and engineers should check the datasheet for the specific standards and marks.
CSA, cUL, EN, UL
Voltage - Input
Input voltage rating or range for which the component is designed to operate. Exceeding this can damage the device. Check the datasheet for absolute maximum ratings and recommended operating conditions to ensure your supply voltage is within safe limits.
85V~264VAC 120V~370VDC
Series
Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
ECE (20W)
Manufacturer'S Part No.
The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
ECE20US05
Datasheet preview
Datasheet PDF viewer
Preview the ECE20US05 datasheet from XP Power to check package, electrical characteristics, application notes, and document evidence before RFQ.
No public product notice document is currently displayed for ECE20US05. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.
Related sourcing options
Recommended products
Explore related DC DC Converters products to compare fit, stock status, datasheets, and sourcing options.
Targeted answers for buyers verifying the exact ECE20US05 ordering code, packaging, stock, datasheet, and replacement path.
What does ECE20US05 mean?
ECE20US05 is the exact ordering code listed for a DC DC Converters component from XP Power. The current package reference is DIP, with listed context including AC/DC CONVERTER 5V 20W. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.
How should buyers verify the ECE20US05 ordering code?
Treat ECE20US05 as the full ordering code during RFQ and engineering review. Confirm the listed DIP package, manufacturer documentation from XP Power, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.
What package is ECE20US05 supplied in?
ECE20US05 is currently listed with package reference DIP from XP Power. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.
Is ECE20US05 currently available?
ECE20US05 is currently marked with stock availability on this page. Before ordering, confirm the package (DIP), listed stock (80366), available quantity (55347), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.
Where can I compare ECE20US05 alternatives?
A mapped alternative list is not currently published for ECE20US05. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.