1020020000 Terminal Blocks - Din Rail, Channel by Weidmüller
1020020000 is a Terminal Blocks - Din Rail, Channel from Weidmüller in manufacturer-listed packaging. It is commonly reviewed for CONN TERM BLK FEED THRU 12-30AWG. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.
Pictures are for reference only. Please contact us for the latest pictures.

- 365-Day GuaranteeAfter-sales support helps buyers handle quality questions with a clearer return and review window.
- Ships within 24-48 HoursAvailable items can move quickly once the quote, quantity, and delivery details are confirmed.
- 100% Anti-Counterfeit TestedParts are checked through authenticity-focused handling and inspection before shipment.
Key specifications
- Part Number
1020020000
- Internal code
TCE000112793
- Package
-
- Manufacturer
- Weidmüller
Key specifications
- Series
W
- Min Quantity
1
- Category
- Connectors, Interconnects
- Sub Category
- Terminal Blocks - Din Rail, Channel
- Description
CONN TERM BLK FEED THRU 12-30AWG
- key Attributes
-
Trust signals
Quality and trust signals
Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.
ISO 9001
Quality management processes for more consistent sourcing and handling.
AS9120B
Aerospace-focused distribution controls for traceability and reliability.
ISO 14001
Environmental management discipline across warehouse and operating workflows.
ESD Control
Electrostatic handling standards to help protect sensitive components.
RFQ checklist
Order process
Confirm the core buying details for 1020020000 before RFQ, PO release, and shipment planning.
- 1
Confirm MPN
Use the exact part number, manufacturer, package, and approval constraints in the RFQ.
- 2
Check stock and price
Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.
- 3
Align documents
Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.
- 4
Arrange shipment
Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.
Before PO release
Part confirmation
- Exact MPN confirmed: 1020020000
- Package to verify: -
Commercial confirmation
- Live stock and lead time confirmed by RFQ
- Final price and tax terms confirmed before PO release
Fulfillment & documents
- Ship-from location: Hong Kong warehouse
- Shipping method: DHL, FedEx, UPS, or buyer forwarder account
Technical parameters
Parameters
Compare grouped 1020020000 parameters from Weidmüller, including package, series, key attributes, and technical values used for engineering and sourcing review.
Export Classifications & Environmental
RoHS Status
RoHS Compliant
Export Classifications & Environmental
HTSUS
8536.69.8000
Export Classifications & Environmental
ECCN Code
EAR99
Export Classifications & Environmental
Moisture Sensitivity Level (MSL)
Not Applicable
Product Attribute
Part Status
Active
Product Attribute
Flammability Rating
UL94 V-0
| Parameter | Value |
|---|---|
RoHS Status Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details. | RoHS Compliant |
REACH SVHC Indicates whether the product contains substances of very high concern as per the REACH regulation. Buyers should verify this for compliance with EU environmental standards, especially when exporting to Europe. Check the manufacturer's declaration or datasheet for accurate SVHC status. | Unknown |
HTSUS Harmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays. | 8536.69.8000 |
ECCN Code Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally. | EAR99 |
Moisture Sensitivity Level (MSL) Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions. | Not Applicable |
| Parameter | Value |
|---|---|
Part Status Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status. | Active |
Flammability Rating UL flammability rating of the material used in the component, indicating its resistance to ignition and flame spread. This is important for safety compliance in end products. Check the rating against your application's required safety standards and environmental conditions. | UL94 V-0 |
Number Of Rows Specifies how many rows of contacts the connector has, typically one, two, or more. This affects the connector's footprint, pin count, and mating force. Choose the row count based on your PCB layout and required pin density. Verify with the datasheet for exact row spacing. | 2 |
Categories Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class. | Connectors, Interconnects |
Published Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions. | 2008 |
REACH Status Shows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold. | REACH Unaffected |
Housing Material Specifies the material of the component's outer casing, such as plastic, metal, or ceramic. This affects durability, thermal performance, and environmental resistance. Verify against datasheet for application-specific requirements like flammability or chemical exposure. | Nylon |
ECCN Export Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues. | EAR99 |
Lead Free Indicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations. | Lead Free |
HTS Code Harmonized Tariff Schedule code used for customs classification of electronic components. Helps determine duties and regulatory requirements. Buyers should confirm the code with a customs broker for accurate shipping. | 8536.69.40.40 |
Factory Lead Time Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions. | 6 Weeks |
Length Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design. | 60mm |
Current Rating Specifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations. | 24A |
Wire Gauge (Min) Specifies the smallest wire size (AWG or mm²) that the terminal, connector, or lug can reliably accept. Important for ensuring proper mechanical and electrical contact. Check the datasheet to confirm compatibility with your chosen wire gauge and avoid overstressing the connection. | 12 AWG |
Termination Style Indicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering. | Screw |
Max Operating Temperature Specifies the highest ambient temperature at which the component reliably functions. Compare this limit with your application's thermal environment to ensure safe operation. Always verify against the datasheet's derating curves and test conditions, as exceeding this value may cause performance degradation or permanent damage. | 120°C |
Additional Feature Lists any extra characteristics or capabilities beyond the standard specifications, such as built-in protection, special mounting options, or enhanced performance. Review these features to ensure they meet your application's specific needs and compare them across similar parts. | STANDARD: UL 94V-0 |
Wire Gauge Or Range - AWG Specifies the acceptable wire gauge or range in American Wire Gauge for this component. Verify compatibility with your cable size to ensure proper connection and current handling. Check the datasheet for exact limits. | 12-30 AWG |
Connector Type Specifies the connector series or family, such as USB, RJ45, or D-Sub. This determines mechanical compatibility, pin layout, and mating standards. Verify against the datasheet to ensure the connector matches your board design and mating counterpart. | Terminal Block |
Manufacturer Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts. | Weidmüller |
Radiation Hardening Indicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet. | No |
Pb-Free Code Indicates whether the component is lead-free per RoHS or other directives. Buyers use this to verify environmental compliance and avoid restricted substances. Always confirm with the datasheet or certificate of compliance. | yes |
Mounting Type Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities. | Through Hole |
Material Flammability Rating Indicates the flammability classification of the insulating material used in the component, typically following UL 94 standards. This rating helps engineers assess fire safety and compliance with regulatory requirements. Check the datasheet for the specific test method and thickness conditions. | UL94 V-0 |
Orientation Indicates the physical mounting orientation of the connector relative to the PCB or mating direction. Engineers compare this to ensure proper alignment in the assembly. Verify against the datasheet for correct placement and mating. | Straight |
Wire Gauge (Max) Indicates the largest wire size that can be terminated or accommodated by this connector or terminal. Compare with your application's wire gauge to ensure proper fit and reliable electrical contact. Verify against the datasheet for specific wire ranges and strip lengths. | 30 AWG |
Number Of Levels Indicates how many tiers or rows of terminals are stacked vertically in a terminal block. This determines the overall height and wiring density of the component. Choose based on your PCB layout and the number of circuits you need to connect in a compact space. | 1 |
Color Specifies the visual color of the component body or housing. Useful for identifying parts in inventory or matching design aesthetics. Verify against the datasheet or physical sample, as color may vary between manufacturers and batches. | Yellow |
Depth Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly. | 5.1mm |
Number Of Decks Indicates how many independent switching levels or decks are stacked in a rotary switch or similar component. Each deck can control a separate circuit. Confirm the number of decks matches your circuit isolation and switching requirements before ordering. | 1 |
Wire/Cable Gauge Specifies the wire gauge size that the connector or terminal is designed to accept. Verify compatibility with your cable's AWG or metric cross-section to ensure proper crimping, current rating, and mechanical retention. Always check the manufacturer's datasheet for the exact range. | 12 AWG |
Voltage Indicates the maximum voltage the component can withstand or operate at, depending on context. Critical for ensuring the part is not overstressed in your application. Always compare with your circuit's voltage levels and consider transient spikes. | 600V |
Max Current Rating Specifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits. | 25A |
Wire Gauge Or Range - Mm² Acceptable wire cross-section range in square millimeters that the terminal can accommodate. This ensures proper clamping force and current-carrying capacity. Verify that your wire size falls within this range to guarantee a secure and safe connection for your application. | 0.5-4mm2 |
Max Supply Voltage Indicates the highest DC or AC voltage that can be safely applied to the power supply pin without risking damage or malfunction. Verify this limit against the datasheet before designing your circuit to ensure reliable operation under all conditions. | 600V |
Width Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure. | 5.1mm |
Voltage - IEC Rated voltage according to International Electrotechnical Commission standards. This value indicates the maximum continuous voltage the component can withstand under specified conditions. Always verify this rating against your application's operating voltage and derating guidelines. | 800V |
Stripping Length Specifies the length of insulation to remove from the wire end for proper termination. Critical for crimping, soldering, or connector assembly. Verify against the connector or terminal manufacturer's requirements to ensure reliable electrical contact and mechanical strength. | 10mm |
Minimum Operating Temperature Specifies the lowest ambient temperature at which the component is guaranteed to function within its electrical and mechanical specifications. Verify this limit against the datasheet for your application's thermal environment, especially for automotive or industrial designs. | -50°C |
Current Specifies the maximum continuous electrical current the component can safely handle under specified conditions. Compare this rating with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for derating and temperature effects. | 21A |
Sub-Categories Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application. | Terminal Blocks - Din Rail, Channel |
Type Select the component category that best matches your application, such as resistor, capacitor, diode, or connector. This classification helps narrow down the correct part family and ensures compatibility with your circuit design. Verify the type against the datasheet to avoid mismatches. | Feed Through |
Safety Approval Lists safety standards and certifications the component complies with, such as UL, CE, or IEC. This is critical for ensuring regulatory compliance in your target market. Always verify the approval status against the latest datasheet or certificate. | UL; CSA; CE |
Approval Agency Indicates the certification body that has tested and approved the component for safety or regulatory compliance. Buyers should verify this matches their target market requirements, and engineers should check the datasheet for the specific standards and marks. | CE, CSA, IEC, NEMKO, UR |
Insulation Material Specifies the dielectric material used to electrically isolate conductors or terminals. This affects voltage ratings, thermal performance, and flammability. Verify compatibility with your operating environment and applicable safety standards before selecting a component for your design. | Thermoplastic, Wemid |
Series Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application. | W |
Height Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations. | 46.5mm |
Voltage - Rated Specifies the maximum continuous voltage the component can safely withstand under normal operating conditions. Engineers compare this rating to the circuit's expected voltage to ensure reliable operation. Always verify against the datasheet for derating factors and environmental conditions. | 8kV |
Current - UL Rated current per UL standard. This value indicates the maximum continuous current the component can safely handle under UL certification conditions. Verify against the datasheet for derating and ambient temperature effects. | 25A |
Weight Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity. | 8.62g |
Manufacturer'S Part No. The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation. | 1020020000 |
Notice documents
PCN / product notice documents
No public PCN / PDN records currently displayed
No public product notice document is currently displayed for 1020020000. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.
Related sourcing options
Recommended products
Explore related Terminal Blocks - Din Rail, Channel products to compare fit, stock status, datasheets, and sourcing options.
Common questions
Product FAQ
Targeted answers for buyers verifying the exact 1020020000 ordering code, packaging, stock, datasheet, and replacement path.
What does 1020020000 mean?
1020020000 is the exact ordering code listed for a Terminal Blocks - Din Rail, Channel component from Weidmüller. The current package reference is -, with listed context including CONN TERM BLK FEED THRU 12-30AWG. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.
How should buyers verify the 1020020000 ordering code?
Treat 1020020000 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from Weidmüller, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.
What package is 1020020000 supplied in?
1020020000 is currently listed with package reference - from Weidmüller. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.
Is 1020020000 currently available?
1020020000 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (21797), available quantity (10138), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.
Where can I compare 1020020000 alternatives?
A mapped alternative list is not currently published for 1020020000. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.