TrustCompo Website Logo | TrustCompo

TE Connectivity / Power Relays, Over 2 Amps

FCA-325-BZ3

FCA-325-BZ3

Quote this part ↓
FCA-325-BZ3 — default product illustration
Illustrative product image. Request actual-lot photos to review markings and packaging.

Part identification

Manufacturer
TE Connectivity
Series
*
View inventory & condition↓Open Datasheet

Order & pricing

Price & availability

Supply subject to market enquiry. No confirmed stock is currently available.

Reference price / piece
Price on request

We reply within 24 hours.

Technical parameters

Detailed specifications

Open Datasheet ↗
Product Attribute51 parameters
Length - TerminationLength - TerminationLength of the termination or lead on components like resistors, capacitors, or connectors, affecting solder joint reliability and mechanical fit. This dimension is crucial for through-hole and surface-mount parts. Ensure the termination length matches your PCB hole depth or pad size. Verify the exact length in the datasheet for proper assembly.
0.0063 inch
Coil Release Voltage (DC)Coil Release Voltage (DC)Specifies the DC voltage at which the relay coil de-energizes and the contacts return to their unpowered state. Verify this value against the datasheet to ensure proper circuit operation and avoid unintended relay behavior.
1.5V
Operating Temperature (Max)Operating Temperature (Max)Specifies the highest ambient temperature at which the component can operate reliably. Check this limit against your application's thermal environment to prevent overheating and ensure long-term stability. Always verify with the datasheet for derating curves.
125°C
SealingSealingIndicates the method used to protect the component from moisture, dust, and other environmental contaminants. Compare sealing types when operating conditions are harsh. Verify the specific sealing standard or rating in the datasheet to ensure reliability in your application.
HERMETICALLY SEALED
Manufacturer's Part No.Manufacturer's Part No.The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
FCA-325-BZ3
Mounting FeatureMounting FeatureDescribes special mechanical characteristics for mounting, such as through-hole, surface mount, or specific clips. Ensures compatibility with your PCB layout and assembly process. Confirm before designing the footprint.
THROUGH HOLE-STRAIGHT MOUNT
Factory Lead TimeFactory Lead TimeIndicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
34 Weeks
Coil Voltage (DC) MaxCoil Voltage (DC) MaxSpecifies the highest DC voltage that can be applied to the relay coil without damage. Verify this against the datasheet to ensure your control circuit matches the relay's operating range and avoids overheating or failure.
28V
Release TimeRelease TimeRelease time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.
16 ms
Reference StandardReference StandardIndicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.
MIL-R-83536
Coil/Input Supply TypeCoil/Input Supply TypeSpecifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.
DC
End Contact PlatingEnd Contact PlatingSpecifies the plating material on the contact surface, affecting conductivity, corrosion resistance, and solderability. Compare across parts to match application requirements. Verify the exact plating thickness and composition in the datasheet, as it impacts long-term reliability and performance.
GOLD
Coil ResistanceCoil ResistanceSpecifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.
290Ohm
Physical DimensionPhysical DimensionOverall dimensions of the component, including length, width, and height. Essential for PCB layout and enclosure design. Confirm these measurements against the datasheet to ensure proper fit and clearance in your assembly.
25.79mm x 25.79mm x 25.4mm
PublishedPublishedPublished indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2003
End Contact MaterialEnd Contact MaterialSpecifies the metal or alloy used for the end contacts of a component, such as a resistor or fuse. This affects solderability, corrosion resistance, and long-term reliability. Verify against the datasheet for harsh environments or high-temperature applications.
Silver Cadmium Oxide
ECCNECCNExport Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Contact Current (DC) MaxContact Current (DC) MaxSpecifies the highest continuous direct current the contact can safely carry without overheating or degrading. Compare this rating with your circuit's expected load, and verify it against the datasheet for derating curves and ambient temperature conditions.
25A
Insulation ResistanceInsulation ResistanceIndicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
100000000Ohm
Relay ActionRelay ActionSpecifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.
MOMENTARY
Coil Current (DC) MaxCoil Current (DC) MaxSpecifies the highest direct current the relay coil is designed to handle continuously. Compare this value with your driver circuit's output to ensure reliable operation and avoid overheating. Always verify against the datasheet for your specific relay model.
0.097A
Contact/Output Supply TypeContact/Output Supply TypeSpecifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.
AC/DC
Relay FunctionRelay FunctionSpecifies the electrical switching configuration of the relay, such as SPDT or DPDT. This determines how many circuits the relay can control and in what sequence. Verify the exact function against the datasheet to ensure it matches your application's switching requirements.
3PDT
Surface MountSurface MountMounting type: surface mount or through-hole. Surface mount components are placed directly on the PCB, saving space and enabling automated assembly. Through-hole components offer stronger mechanical bonds. Verify the mounting style matches your PCB design and assembly process.
NO
Termination TypeTermination TypeMethod used to terminate the contact, such as solder, crimp, or press-fit. This determines how the component connects to the PCB or wire. Choose the termination type based on your assembly process and reliability requirements. Confirm with the datasheet for compatibility.
SOLDER
Coil Operate Voltage (DC)Coil Operate Voltage (DC)Specifies the DC voltage at which the relay coil reliably energizes and the contacts switch. Compare this value with the coil release voltage and the circuit supply to ensure proper operation. Verify against the datasheet for tolerance and temperature effects.
18V
Coil PowerCoil PowerPower consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.
2720mW
Number of TerminationsNumber of TerminationsIndicates the total number of electrical connection points on the component, such as pins or pads. This is critical for PCB footprint design and assembly. Verify it matches the package specification to ensure proper soldering and connectivity.
11
Part StatusPart StatusLifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
HTS CodeHTS CodeHarmonized Tariff Schedule code used for customs classification of electronic components. Helps determine duties and regulatory requirements. Buyers should confirm the code with a customs broker for accurate shipping.
8536.41.00.50
Body Length or DiameterBody Length or DiameterSpecifies the physical size of the component body, either its length for rectangular parts or diameter for cylindrical ones. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure clearance and proper mounting in your enclosure or assembly.
25.79mm
REACH StatusREACH StatusShows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.
REACH Unaffected
Body HeightBody HeightHeight of the switch body from the mounting surface to the top, excluding the actuator. Critical for clearance in enclosures and for PCB assembly. Verify it matches your mechanical design constraints and soldering process requirements.
25.4mm
Relay FormRelay FormSpecifies the contact arrangement of the relay, such as SPST, SPDT, or DPDT. This determines how many circuits the relay can switch and in what configuration. Verify the form against your application requirements to ensure proper switching functionality.
3 FORM C
Operate TimeOperate TimeOperate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.
16 ms
Electrical LifeElectrical LifeNumber of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.
50000 Cycle(s)
Coil VoltageCoil VoltageSpecifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.
28V
Relay TypeRelay TypeClassifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.
POWER/SIGNAL RELAY
Body BreadthBody BreadthMeasure the widest dimension of the component body, excluding leads and terminals. This attribute helps determine PCB footprint compatibility and mechanical fit. Verify against the datasheet drawing for accurate placement and clearance in your assembly.
25.79 mm
WeightWeightSpecifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.
82g
Operating Temperature (Min)Operating Temperature (Min)Specifies the lowest ambient temperature at which the component remains fully functional. Check this limit against your application's environmental extremes to ensure reliable operation. Exceeding this minimum may cause performance degradation or failure, so always verify with the datasheet.
-70°C
Contact Current (AC) - MaxContact Current (AC) - MaxSpecifies the highest alternating current the contacts can safely carry under normal operating conditions. Compare this value with your circuit's expected AC load to ensure reliable switching and avoid overheating. Always verify against the datasheet for derating factors and temperature limits.
25A
Contact Voltage (AC) - MaxContact Voltage (AC) - MaxMaximum AC voltage that can be safely applied across the contacts of a relay, switch, or connector. Exceeding this rating may cause arcing or insulation breakdown. Always verify this limit against the datasheet for your specific load conditions.
115V
Contact Voltage (DC) - MaxContact Voltage (DC) - MaxMaximum DC voltage that can be safely applied across the contacts of a relay, switch, or connector. Exceeding this rating may cause arcing or insulation breakdown. Always verify this limit against the datasheet for your specific load conditions.
28V
ManufacturerManufacturerIdentifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
PCB Hole CountPCB Hole CountTotal number of drilled holes in the PCB footprint for through-hole mounting or connector pins. Compare this count with your assembly drawing to ensure the board layout matches the component's mechanical dimensions and pin pattern.
11
Input Switching Control TypeInput Switching Control TypeSpecifies the method used to control input switching, such as AC, DC, or pulse. This determines how the device is triggered and affects compatibility with your control signal. Verify the required control type against your application's drive circuit and the datasheet specifications.
Random
CategoriesCategoriesLists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Relays
SeriesSeriesIndicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
*
Sub-CategoriesSub-CategoriesIndicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Power Relays, Over 2 Amps
Dielectric Strength Between Open ContactsDielectric Strength Between Open ContactsIndicates the maximum voltage that can be applied across open contacts without causing an arc or breakdown. Critical for relay and switch isolation ratings. Verify against datasheet for safety margins in your application.
1250 Vrms
Export Classifications & Environmental5 parameters
RoHS StatusRoHS StatusIndicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS non-compliant
JESD-609 CodeJESD-609 CodeThis code indicates the terminal finish material per JESD-609 standard. It helps identify the plating type for soldering compatibility and environmental compliance. Check the datasheet for the exact code and its meaning.
e0
Moisture Sensitivity Level (MSL)Moisture Sensitivity Level (MSL)Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
Not Applicable
HTSUSHTSUSHarmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.41.0050
ECCN CodeECCN CodeExport Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
Product Parameter1 parameters
Terminal FinishTerminal FinishSpecifies the plating material on component terminals, affecting solderability, corrosion resistance, and long-term reliability. Compare finishes like tin, gold, or silver for your assembly process and environmental requirements. Verify against datasheet for compliance.
Tin/Lead (Sn/Pb)

Technical document

FCA-325-BZ3 — Datasheet

Open the manufacturer document for package drawings and electrical specifications.

Open Datasheet

Check the lot

Photos, traceability & inspection

Confirm what is available for the quoted lot, and agree any extra inspection or document requirements before purchase.

Markings & packaging

Request actual-lot photos, top markings, manufacturer labels and reel, tray or tube details. Reference images are not evidence of a specific lot.

Documents & traceability

Tell us whether you need a CoC, traceability records or compliance documents. Availability must be confirmed for the selected source and lot.

Inspection & testing

Agree the inspection scope, test reports, timing and any charges during quotation. Share customer acceptance requirements before the order is locked.

Quality controls →

Plan your purchase

Payment, delivery & documents

Review how the order will be paid, packed and shipped before committing your purchase.

Packing & delivery

Most orders ship from Hong Kong. DHL, FedEx, UPS and SF International can be arranged according to destination and service availability.

DHLFedExUPS
  • For our own stock, we dispatch on the same day or the next day after confirming the shipping method with you.
  • Prefer your own logistics? Ask for pickup or handover to your designated forwarder; confirm carrier-account or label arrangements before booking.
  • Agree freight, insurance, duties, taxes and delivery responsibilities in the quotation. DDP requests are reviewed separately.
  • International express transit is typically 3–7 business days after carrier handover. This is guidance, not a dispatch or arrival guarantee.
  • Payment confirmation, inspection, photo approval, export documents and carrier booking affect release. Share ESD, moisture protection, label and packing requirements early.
Read full terms →
Payment & invoices

Quotes are in USD. T/T bank transfer is a standard payment option; other channels depend on the order and destination.

  • PI and commercial invoices can be provided for approved orders. Confirm the payee, currency, amount and payment terms on the order documents.
  • PayPal and other channels may be available subject to regional, banking and order conditions. Credit terms require application and approval.
  • Quotes exclude tax unless stated in writing. Confirm payment charges, freight and destination costs during quote review.
Read full terms →
Returns & order changes

Review the cancellation and claim conditions for your quoted lot before confirming an order.

  • Standard-stock cancellation may be requested before packing or shipment release. Backorder, shortage and committed channel-sourced material may be NCNR once supply is locked.
  • Returns require prior written authorization and an RMA reference. Non-quality returns are generally not accepted for confirmed special or NCNR orders.
  • Report quality issues promptly with the order reference, affected quantity, photos and issue description. Keep original labels and packaging for review.
Read full terms →

Order & pricing

Ready to discuss FCA-325-BZ3?

Your part, selected lot and quantity go with the enquiry. Add destination, delivery target and any photo, testing or EUU requirements.

Minimum order: 1 pieces

We reply within 24 hours.