FCA-325-BZ3 Power Relays, Over 2 Amps by TE Connectivity
FCA-325-BZ3 is a Power Relays, Over 2 Amps from TE Connectivity in manufacturer-listed packaging. It is commonly reviewed for FCA-325-BZ3. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.
Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.
4 certifications
ISO 9001
Quality management processes for more consistent sourcing and handling.
AS9120B
Aerospace-focused distribution controls for traceability and reliability.
ISO 14001
Environmental management discipline across warehouse and operating workflows.
ESD Control
Electrostatic handling standards to help protect sensitive components.
RFQ checklist
Order process
Confirm the core buying details for FCA-325-BZ3 before RFQ, PO release, and shipment planning.
1
Confirm MPN
Use the exact part number, manufacturer, package, and approval constraints in the RFQ.
2
Check stock and price
Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.
3
Align documents
Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.
4
Arrange shipment
Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.
Before PO release
Part confirmation
Exact MPN confirmed: FCA-325-BZ3
Package to verify: -
Commercial confirmation
Live stock and lead time confirmed by RFQ
Final price and tax terms confirmed before PO release
Fulfillment & documents
Ship-from location: Hong Kong warehouse
Shipping method: DHL, FedEx, UPS, or buyer forwarder account
Technical parameters
Parameters
Compare grouped FCA-325-BZ3 parameters from TE Connectivity, including package, series, key attributes, and technical values used for engineering and sourcing review.
Product Attribute
Termination Type
SOLDER
Product Attribute
Part Status
Active
Product Attribute
Manufacturer
TE Connectivity
Product Attribute
REACH Status
REACH Unaffected
Product Attribute
ECCN
EAR99
Product Attribute
Published
2003
FCA-325-BZ3 Product Attribute
Parameter
Value
Termination Type
Method used to terminate the contact, such as solder, crimp, or press-fit. This determines how the component connects to the PCB or wire. Choose the termination type based on your assembly process and reliability requirements. Confirm with the datasheet for compatibility.
SOLDER
Part Status
Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
Manufacturer
Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
REACH Status
Shows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.
REACH Unaffected
ECCN
Export Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Published
Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2003
Insulation Resistance
Indicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
100000000Ohm
Relay Action
Specifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.
MOMENTARY
Coil/Input Supply Type
Specifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.
DC
Input Switching Control Type
Specifies the method used to control input switching, such as AC, DC, or pulse. This determines how the device is triggered and affects compatibility with your control signal. Verify the required control type against your application's drive circuit and the datasheet specifications.
Random
Contact/Output Supply Type
Specifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.
AC/DC
Sub-Categories
Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Power Relays, Over 2 Amps
Categories
Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Relays
Factory Lead Time
Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
34 Weeks
Series
Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
*
Electrical Life
Number of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.
50000 Cycle(s)
Sealing
Indicates the method used to protect the component from moisture, dust, and other environmental contaminants. Compare sealing types when operating conditions are harsh. Verify the specific sealing standard or rating in the datasheet to ensure reliability in your application.
HERMETICALLY SEALED
Surface Mount
Mounting type: surface mount or through-hole. Surface mount components are placed directly on the PCB, saving space and enabling automated assembly. Through-hole components offer stronger mechanical bonds. Verify the mounting style matches your PCB design and assembly process.
NO
Number Of Terminations
Indicates the total number of electrical connection points on the component, such as pins or pads. This is critical for PCB footprint design and assembly. Verify it matches the package specification to ensure proper soldering and connectivity.
11
End Contact Plating
Specifies the plating material on the contact surface, affecting conductivity, corrosion resistance, and solderability. Compare across parts to match application requirements. Verify the exact plating thickness and composition in the datasheet, as it impacts long-term reliability and performance.
GOLD
Relay Type
Classifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.
POWER/SIGNAL RELAY
Coil Release Voltage (DC)
Specifies the DC voltage at which the relay coil de-energizes and the contacts return to their unpowered state. Verify this value against the datasheet to ensure proper circuit operation and avoid unintended relay behavior.
1.5V
Operating Temperature (Max)
Specifies the highest ambient temperature at which the component can operate reliably. Check this limit against your application's thermal environment to prevent overheating and ensure long-term stability. Always verify with the datasheet for derating curves.
125°C
Contact Voltage (AC) - Max
Maximum AC voltage that can be safely applied across the contacts of a relay, switch, or connector. Exceeding this rating may cause arcing or insulation breakdown. Always verify this limit against the datasheet for your specific load conditions.
115V
HTS Code
Harmonized Tariff Schedule code used for customs classification of electronic components. Helps determine duties and regulatory requirements. Buyers should confirm the code with a customs broker for accurate shipping.
8536.41.00.50
Contact Voltage (DC) - Max
Maximum DC voltage that can be safely applied across the contacts of a relay, switch, or connector. Exceeding this rating may cause arcing or insulation breakdown. Always verify this limit against the datasheet for your specific load conditions.
28V
Coil Resistance
Specifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.
290Ohm
Mounting Feature
Describes special mechanical characteristics for mounting, such as through-hole, surface mount, or specific clips. Ensures compatibility with your PCB layout and assembly process. Confirm before designing the footprint.
THROUGH HOLE-STRAIGHT MOUNT
Dielectric Strength Between Open Contacts
Indicates the maximum voltage that can be applied across open contacts without causing an arc or breakdown. Critical for relay and switch isolation ratings. Verify against datasheet for safety margins in your application.
1250 Vrms
Body Height
Height of the switch body from the mounting surface to the top, excluding the actuator. Critical for clearance in enclosures and for PCB assembly. Verify it matches your mechanical design constraints and soldering process requirements.
25.4mm
Body Length Or Diameter
Specifies the physical size of the component body, either its length for rectangular parts or diameter for cylindrical ones. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure clearance and proper mounting in your enclosure or assembly.
25.79mm
Weight
Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.
82g
Release Time
Release time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.
16 ms
PCB Hole Count
Total number of drilled holes in the PCB footprint for through-hole mounting or connector pins. Compare this count with your assembly drawing to ensure the board layout matches the component's mechanical dimensions and pin pattern.
11
Coil Power
Power consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.
2720mW
Body Breadth
Measure the widest dimension of the component body, excluding leads and terminals. This attribute helps determine PCB footprint compatibility and mechanical fit. Verify against the datasheet drawing for accurate placement and clearance in your assembly.
25.79 mm
Physical Dimension
Overall dimensions of the component, including length, width, and height. Essential for PCB layout and enclosure design. Confirm these measurements against the datasheet to ensure proper fit and clearance in your assembly.
25.79mm x 25.79mm x 25.4mm
Length - Termination
Length of the termination or lead on components like resistors, capacitors, or connectors, affecting solder joint reliability and mechanical fit. This dimension is crucial for through-hole and surface-mount parts. Ensure the termination length matches your PCB hole depth or pad size. Verify the exact length in the datasheet for proper assembly.
0.0063 inch
Reference Standard
Indicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.
MIL-R-83536
Coil Voltage
Specifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.
28V
Operating Temperature (Min)
Specifies the lowest ambient temperature at which the component remains fully functional. Check this limit against your application's environmental extremes to ensure reliable operation. Exceeding this minimum may cause performance degradation or failure, so always verify with the datasheet.
-70°C
Coil Voltage (DC) Max
Specifies the highest DC voltage that can be applied to the relay coil without damage. Verify this against the datasheet to ensure your control circuit matches the relay's operating range and avoids overheating or failure.
28V
End Contact Material
Specifies the metal or alloy used for the end contacts of a component, such as a resistor or fuse. This affects solderability, corrosion resistance, and long-term reliability. Verify against the datasheet for harsh environments or high-temperature applications.
Silver Cadmium Oxide
Coil Operate Voltage (DC)
Specifies the DC voltage at which the relay coil reliably energizes and the contacts switch. Compare this value with the coil release voltage and the circuit supply to ensure proper operation. Verify against the datasheet for tolerance and temperature effects.
18V
Relay Form
Specifies the contact arrangement of the relay, such as SPST, SPDT, or DPDT. This determines how many circuits the relay can switch and in what configuration. Verify the form against your application requirements to ensure proper switching functionality.
3 FORM C
Relay Function
Specifies the electrical switching configuration of the relay, such as SPDT or DPDT. This determines how many circuits the relay can control and in what sequence. Verify the exact function against the datasheet to ensure it matches your application's switching requirements.
3PDT
Operate Time
Operate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.
16 ms
Coil Current (DC) Max
Specifies the highest direct current the relay coil is designed to handle continuously. Compare this value with your driver circuit's output to ensure reliable operation and avoid overheating. Always verify against the datasheet for your specific relay model.
0.097A
Manufacturer'S Part No.
The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
FCA-325-BZ3
Contact Current (DC) Max
Specifies the highest continuous direct current the contact can safely carry without overheating or degrading. Compare this rating with your circuit's expected load, and verify it against the datasheet for derating curves and ambient temperature conditions.
25A
Contact Current (AC) - Max
Specifies the highest alternating current the contacts can safely carry under normal operating conditions. Compare this value with your circuit's expected AC load to ensure reliable switching and avoid overheating. Always verify against the datasheet for derating factors and temperature limits.
Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS non-compliant
JESD-609 Code
This code indicates the terminal finish material per JESD-609 standard. It helps identify the plating type for soldering compatibility and environmental compliance. Check the datasheet for the exact code and its meaning.
e0
HTSUS
Harmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.41.0050
ECCN Code
Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
Moisture Sensitivity Level (MSL)
Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
Not Applicable
FCA-325-BZ3 Product Parameter
Parameter
Value
Terminal Finish
Specifies the plating material on component terminals, affecting solderability, corrosion resistance, and long-term reliability. Compare finishes like tin, gold, or silver for your assembly process and environmental requirements. Verify against datasheet for compliance.
Tin/Lead (Sn/Pb)
Datasheet preview
Datasheet PDF viewer
Preview the FCA-325-BZ3 datasheet from TE Connectivity to check package, electrical characteristics, application notes, and document evidence before RFQ.
No public product notice document is currently displayed for FCA-325-BZ3. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.
Related sourcing options
Recommended products
Explore related Power Relays, Over 2 Amps products to compare fit, stock status, datasheets, and sourcing options.
Targeted answers for buyers verifying the exact FCA-325-BZ3 ordering code, packaging, stock, datasheet, and replacement path.
What does FCA-325-BZ3 mean?
FCA-325-BZ3 is the exact ordering code listed for a Power Relays, Over 2 Amps component from TE Connectivity. The current package reference is -, with listed context including FCA-325-BZ3. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.
How should buyers verify the FCA-325-BZ3 ordering code?
Treat FCA-325-BZ3 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from TE Connectivity, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.
What package is FCA-325-BZ3 supplied in?
FCA-325-BZ3 is currently listed with package reference - from TE Connectivity. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.
Is FCA-325-BZ3 currently available?
FCA-325-BZ3 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (20156), available quantity (16611), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.
Where can I compare FCA-325-BZ3 alternatives?
A mapped alternative list is not currently published for FCA-325-BZ3. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.