TrustCompo Website Logo | TrustCompo

TE Connectivity / Power Relays, Over 2 Amps

KUP-14D15F-24

RELAY GEN PURPOSE 3PDT 10A 24V

Quote this part ↓
KUP-14D15F-24 — default product illustration
Illustrative product image. Request actual-lot photos to review markings and packaging.

Part identification

Manufacturer
TE Connectivity
Series
KUP
View inventory & condition↓Open Datasheet

Order & pricing

Price & availability

Supply subject to market enquiry. No confirmed stock is currently available.

Reference price / piece
Price on request

We reply within 24 hours.

Technical parameters

Detailed specifications

Open Datasheet ↗
Product Attribute53 parameters
SealingSealingIndicates the method used to protect the component from moisture, dust, and other environmental contaminants. Compare sealing types when operating conditions are harsh. Verify the specific sealing standard or rating in the datasheet to ensure reliability in your application.
DUST PROOF
ELV ComplianceELV ComplianceIndicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.
Non-Compliant
Factory Lead TimeFactory Lead TimeIndicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
20 Weeks
PackagingPackagingIndicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.
Bulk
Number of PinsNumber of PinsTotal number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.
11
HeightHeightPhysical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.
50mm
WeightWeightSpecifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.
84.708375g
Contact MaterialContact MaterialSpecifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.
Silver Cadmium Oxide (AgCdO)
Lifecycle StatusLifecycle StatusCurrent stage in the product's lifecycle, such as Active, Obsolete, or End of Life. This indicates availability and long-term supply risk. Check this before designing in a part to ensure it will be available for your product's production lifetime.
ACTIVE (Last Updated: 3 days ago)
Coil CurrentCoil CurrentSpecifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.
51mA
Max Voltage Rating (AC)Max Voltage Rating (AC)Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.
240V
Lead FreeLead FreeIndicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.
Not Applicable
DepthDepthPhysical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.
35.71mm
Part StatusPart StatusLifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
Relay ActionRelay ActionSpecifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.
MOMENTARY
Contact FormContact FormSpecifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.
3PDT (3 Form C)
Operating TemperatureOperating TemperatureSpecifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-45°C~70°C
Contact/Output Supply TypeContact/Output Supply TypeSpecifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.
AC/DC
Mounting TypeMounting TypeSpecifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
Socket, Socketable
Coil/Input Supply TypeCoil/Input Supply TypeSpecifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.
DC
Reference StandardReference StandardIndicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.
CSA; UL
Sub-CategoriesSub-CategoriesIndicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Power Relays, Over 2 Amps
Coil ResistanceCoil ResistanceSpecifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.
472Ohm
Operate TimeOperate TimeOperate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.
15ms
Voltage - Rated ACVoltage - Rated ACMaximum AC voltage that the component can safely withstand under specified conditions. This rating is critical for insulation and safety margins. Always compare it with the operating voltage in your circuit and derate according to the datasheet guidelines.
240V
SeriesSeriesIndicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
KUP
HTS CodeHTS CodeHarmonized Tariff Schedule code used for customs classification of electronic components. Helps determine duties and regulatory requirements. Buyers should confirm the code with a customs broker for accurate shipping.
8536.41.00.20
Manufacturer's Part No.Manufacturer's Part No.The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
KUP-14D15F-24
Physical DimensionPhysical DimensionOverall dimensions of the component, including length, width, and height. Essential for PCB layout and enclosure design. Confirm these measurements against the datasheet to ensure proper fit and clearance in your assembly.
38.9mm x 35.7mm x 48.4mm
WidthWidthPhysical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.
35.687mm
Must Operate VoltageMust Operate VoltageDefines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.
18VDC
Coil Voltage (DC)Coil Voltage (DC)Specifies the nominal DC voltage required to energize the relay coil. Verify this matches your control circuit supply to ensure reliable switching. Check the datasheet for allowable tolerance and minimum pickup voltage.
24V
ManufacturerManufacturerIdentifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
Max Current RatingMax Current RatingSpecifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits.
10A
Relay TypeRelay TypeClassifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.
General Purpose
Max Voltage Rating (DC)Max Voltage Rating (DC)Specifies the maximum continuous direct current voltage the component can safely withstand. Engineers compare this rating to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet for derating guidelines and environmental conditions.
32V
Termination StyleTermination StyleIndicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.
Plug In, Quick Connect - 0.187 (4.7mm)
Body BreadthBody BreadthMeasure the widest dimension of the component body, excluding leads and terminals. This attribute helps determine PCB footprint compatibility and mechanical fit. Verify against the datasheet drawing for accurate placement and clearance in your assembly.
35.7 mm
Switching VoltageSwitching VoltageSpecifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.
240VAC -Max
TerminationTerminationDescribes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.
Plug, Solder
Coil VoltageCoil VoltageSpecifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.
24VDC
Coil InsulationCoil InsulationInsulation class or material used for the coil winding in relays, transformers, or solenoids. This determines the maximum operating temperature and dielectric strength. Choose a class that matches your thermal environment to prevent premature failure and ensure long-term reliability.
Class B
Contact PlatingContact PlatingSpecifies the metal coating applied to the contact surfaces of connectors, switches, or relays. This finish affects conductivity, corrosion resistance, and durability. Engineers should verify the plating material and thickness against the datasheet to ensure reliable performance in the intended environment.
Gold
CategoriesCategoriesLists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Relays
Release TimeRelease TimeRelease time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.
10ms
Mounting TypeMounting TypeSpecifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Socketable
Coil PowerCoil PowerPower consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.
1.25W
Contact Voltage Rating (AC)Contact Voltage Rating (AC)Maximum AC voltage that the contacts can safely handle under normal operating conditions. Exceeding this rating can cause arcing or insulation breakdown. Verify that your application's AC voltage is within this limit to ensure reliable and safe operation of the connector or relay.
240V
LengthLengthSpecifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.
38.89mm
Throw ConfigurationThrow ConfigurationSpecifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.
3PDT
Coil TypeCoil TypeSpecifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.
Non Latching
Electrical LifeElectrical LifeNumber of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.
100000 Cycle(s)
Radiation HardeningRadiation HardeningIndicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet.
No
Export Classifications & Environmental3 parameters
ECCN CodeECCN CodeExport Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
Moisture Sensitivity Level (MSL)Moisture Sensitivity Level (MSL)Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
1 (Unlimited)
RoHS StatusRoHS StatusIndicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS Compliant

Technical document

KUP-14D15F-24 — Datasheet

Open the manufacturer document for package drawings and electrical specifications.

Open Datasheet

Check the lot

Photos, traceability & inspection

Confirm what is available for the quoted lot, and agree any extra inspection or document requirements before purchase.

Markings & packaging

Request actual-lot photos, top markings, manufacturer labels and reel, tray or tube details. Reference images are not evidence of a specific lot.

Documents & traceability

Tell us whether you need a CoC, traceability records or compliance documents. Availability must be confirmed for the selected source and lot.

Inspection & testing

Agree the inspection scope, test reports, timing and any charges during quotation. Share customer acceptance requirements before the order is locked.

Quality controls →

Plan your purchase

Payment, delivery & documents

Review how the order will be paid, packed and shipped before committing your purchase.

Packing & delivery

Most orders ship from Hong Kong. DHL, FedEx, UPS and SF International can be arranged according to destination and service availability.

DHLFedExUPS
  • For our own stock, we dispatch on the same day or the next day after confirming the shipping method with you.
  • Prefer your own logistics? Ask for pickup or handover to your designated forwarder; confirm carrier-account or label arrangements before booking.
  • Agree freight, insurance, duties, taxes and delivery responsibilities in the quotation. DDP requests are reviewed separately.
  • International express transit is typically 3–7 business days after carrier handover. This is guidance, not a dispatch or arrival guarantee.
  • Payment confirmation, inspection, photo approval, export documents and carrier booking affect release. Share ESD, moisture protection, label and packing requirements early.
Read full terms →
Payment & invoices

Quotes are in USD. T/T bank transfer is a standard payment option; other channels depend on the order and destination.

  • PI and commercial invoices can be provided for approved orders. Confirm the payee, currency, amount and payment terms on the order documents.
  • PayPal and other channels may be available subject to regional, banking and order conditions. Credit terms require application and approval.
  • Quotes exclude tax unless stated in writing. Confirm payment charges, freight and destination costs during quote review.
Read full terms →
Returns & order changes

Review the cancellation and claim conditions for your quoted lot before confirming an order.

  • Standard-stock cancellation may be requested before packing or shipment release. Backorder, shortage and committed channel-sourced material may be NCNR once supply is locked.
  • Returns require prior written authorization and an RMA reference. Non-quality returns are generally not accepted for confirmed special or NCNR orders.
  • Report quality issues promptly with the order reference, affected quantity, photos and issue description. Keep original labels and packaging for review.
Read full terms →

Order & pricing

Ready to discuss KUP-14D15F-24?

Your part, selected lot and quantity go with the enquiry. Add destination, delivery target and any photo, testing or EUU requirements.

Minimum order: 1 pieces

We reply within 24 hours.