SeriesSeriesIndicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
Greenpar
Insulation MaterialInsulation MaterialSpecifies the dielectric material used to isolate conductive parts in components such as transformers, connectors, or cables. This affects thermal resistance, voltage withstand capability, and flammability rating. Verify the material against datasheet specifications for safety and performance in your application.
Polytetrafluoroethylene
SubcategorySubcategoryA more specific classification within the main product category, such as 'Ceramic Capacitor' under 'Capacitors'. This helps narrow down search results and compare similar components. Use it to filter products with similar characteristics and intended applications.
Other RF Connectors
Panel ThicknessPanel ThicknessSpecifies the thickness of the mounting panel for which the component is designed. Verify this dimension against your enclosure or panel cutout to ensure proper fit and sealing. Critical for connectors, switches, and indicators that mount through a panel.
9.5mm
Mating CyclesMating CyclesIndicates the number of times a connector can be mated and unmated before performance degrades. Compare this rating when selecting connectors for frequent disconnection applications. Verify against the datasheet to ensure durability matches your expected usage.
500
TerminationTerminationDescribes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.
Crimp
PublishedPublishedPublished indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2006
Connector StyleConnector StyleStyle or type of the connector, such as D-sub, USB, RJ45, or circular, determining its mechanical interface and electrical performance. Choose the style that matches your mating connector and application environment. Verify the connector style in the datasheet to ensure proper fit, pinout, and durability for your design.
N Type
VSWRVSWRVoltage standing wave ratio indicates how well the component's impedance matches its transmission line. Lower values mean better matching and less signal reflection. Compare VSWR across similar parts to ensure efficient power transfer in RF systems, and verify against the datasheet for your operating frequency.
1.3
Part StatusPart StatusLifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Obsolete
Mounting TypeMounting TypeSpecifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
Bulkhead, Cable, Front Side Nut, Panel
Body MaterialBody MaterialDefines the insulating material of the connector body, impacting mechanical strength, temperature rating, and flammability. Essential for environmental compliance and durability. Confirm material grade and UL rating in the datasheet before design-in.
Brass
Fastening TypeFastening TypeSpecifies the mechanical method used to secure the component to a PCB or panel, such as screw, snap-in, or adhesive. This affects assembly time, reliability under vibration, and serviceability. Verify compatibility with your mounting process and enclosure design before ordering.
Threaded
ELV ComplianceELV ComplianceIndicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.
Compliant
Polarization KeyPolarization KeyA physical feature on connectors or housings that ensures correct mating orientation. This prevents mismating and potential damage. Verify the key type and position against the datasheet to ensure compatibility with your mating connector and application.
POLARIZED HOUSING
Radiation HardeningRadiation HardeningIndicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet.
No
Mounting TypeMounting TypeSpecifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Panel Mount
PackagingPackagingIndicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.
Bulk
MIL ConformanceMIL ConformanceIndicates whether the component meets military specifications (MIL-SPEC) for reliability, performance, and environmental resistance. This is critical for defense, aerospace, and high-reliability applications. Verify the specific MIL standard and test conditions in the datasheet.
NO
Insertion LossInsertion LossInsertion loss measures signal power reduction caused by placing a component in a transmission path. Lower values indicate better performance. Compare this parameter across similar components to ensure signal integrity in your application, and verify it against the datasheet for your operating frequency.
0.3 dB
Contact TerminationContact TerminationSpecifies how the contact is electrically and mechanically connected to the wire or PCB. Common types include solder, crimp, and press-fit. Choose based on assembly method and reliability requirements. Verify compatibility with your wire gauge or board thickness in the datasheet.
Solder
Cable TypeCable TypeSelect the cable construction that matches your application, such as coaxial, ribbon, or twisted pair. This determines signal integrity, flexibility, and shielding. Verify the exact type against the datasheet to ensure compatibility with connectors and environmental requirements.
RG-58C/U
LengthLengthSpecifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.
42.8mm
Operating TemperatureOperating TemperatureSpecifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-65°C~165°C
Mounting FeatureMounting FeatureDescribes special mechanical characteristics for mounting, such as through-hole, surface mount, or specific clips. Ensures compatibility with your PCB layout and assembly process. Confirm before designing the footprint.
Bulkhead - Front Side Nut
Connector TypeConnector TypeSpecifies the connector series or family, such as USB, RJ45, or D-Sub. This determines mechanical compatibility, pin layout, and mating standards. Verify against the datasheet to ensure the connector matches your board design and mating counterpart.
Jack, Female Socket
ECCNECCNExport Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
FrequencyFrequencyOperating frequency of the component, typically the clock or switching frequency. This determines the speed of operation and affects power dissipation and signal integrity. Verify the frequency range against your application's requirements and the datasheet specifications.
-11GHz
OrientationOrientationIndicates the physical mounting orientation of the connector relative to the PCB or mating direction. Engineers compare this to ensure proper alignment in the assembly. Verify against the datasheet for correct placement and mating.
Straight
Wire/Cable TypeWire/Cable TypeSpecifies the wire or cable construction the connector is designed to terminate, such as stranded, solid, or coaxial. Engineers use this to match the connector with the correct wire gauge and insulation. Always confirm compatibility with the cable specification.
Coaxial
ManufacturerManufacturerIdentifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
Factory Lead TimeFactory Lead TimeIndicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
8 Weeks
Voltage - RatedVoltage - RatedSpecifies the maximum continuous voltage the component can safely withstand under normal operating conditions. Engineers compare this rating to the circuit's expected voltage to ensure reliable operation. Always verify against the datasheet for derating factors and environmental conditions.
1000V
ReliabilityReliabilityReliability rating or qualification indicates the component's expected performance under specified conditions over time. Compare reliability levels when selecting parts for critical applications, and verify the qualification standard against the datasheet to ensure it meets your requirements.
COMMERCIAL
IEC ConformanceIEC ConformanceIndicates whether the component meets International Electrotechnical Commission standards. Check this attribute to ensure compatibility with international safety and performance requirements. Verify the specific IEC standard listed in the datasheet for your application.
NO
Pb-Free CodePb-Free CodeIndicates whether the component is lead-free per RoHS or other directives. Buyers use this to verify environmental compliance and avoid restricted substances. Always confirm with the datasheet or certificate of compliance.
yes
Dielectric MaterialDielectric MaterialInsulating material used in capacitors, connectors, or substrates, determining electrical performance, temperature stability, and insulation resistance. Choose among ceramic, tantalum, or polymer types based on capacitance, voltage, and frequency requirements. Always confirm the dielectric specification in the datasheet for your application's operating conditions.
Polytetrafluoroethylene (PTFE)
CategoriesCategoriesLists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Connectors, Interconnects
ImpedanceImpedanceSpecifies the opposition to alternating current in a component, typically for RF or high-speed signal paths. Compare values to ensure proper impedance matching and signal integrity. Verify against the datasheet for your application frequency.
50Ohm
Working VoltageWorking VoltageDefines the maximum continuous voltage that can be applied across the component during normal operation without degradation. This is critical for capacitors, connectors, and insulation ratings. Check the datasheet to confirm the safe operating range and any environmental derating.
1kV
Total Number of ContactsTotal Number of ContactsSpecifies the total number of electrical contact points in the connector. This determines the maximum number of circuits that can be connected. Verify against the datasheet to ensure it matches your required pin count and mating connector configuration.
1
Number of PortsNumber of PortsIndicates how many independent connection points or interfaces the component provides. Compare this when selecting connectors, switches, or modules for multi-channel designs. Verify against the datasheet to ensure the port count matches your system's required I/O configuration.
1
GenderGenderGender indicates whether a connector is male (with pins) or female (with sockets). This is critical for mating compatibility in cable assemblies and board-to-board connections. Verify gender against the mating connector part number to ensure proper fit and reliable electrical contact.
Male
DIN ConformanceDIN ConformanceIndicates whether the component complies with German DIN standards. Verify this attribute when the application requires specific mechanical, electrical, or safety specifications defined by DIN. Check the datasheet for the exact DIN number and edition to ensure compatibility with your system.
NO
Sub-CategoriesSub-CategoriesIndicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Coaxial Connectors (RF)
Manufacturer's Part No.Manufacturer's Part No.The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
1-1478224-0
OptionOptionDescribes the specific configuration or variant of the component, such as packaging, lead form, or mounting style. Engineers compare options to match exact design requirements. Always check the option code against the datasheet to ensure compatibility with your application.
GENERAL PURPOSE
Shield TerminationShield TerminationIndicates how the cable shield is terminated, such as soldered, crimped, or clamped. This affects grounding effectiveness and EMI performance. Verify the method against the datasheet to ensure proper shielding and signal integrity in your application.
Clamp
Insulation ResistanceInsulation ResistanceIndicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
5GOhm
Cable GroupCable GroupIdentifies the category or group of cable that is compatible with the component, such as flat ribbon, twisted pair, or coaxial. This attribute helps ensure the correct cable type is selected for the connector or module. Always confirm with the datasheet for exact cable specifications.
RG-58C, 141A
REACH StatusREACH StatusShows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.
Vendor Undefined
Center Contact PlatingCenter Contact PlatingDefines the plating material on the center contact of coaxial connectors or similar components. This finish impacts signal integrity, wear resistance, and mating durability. Check the datasheet for recommended plating when matching connectors for high-frequency or repeated use.
HTSUSHTSUSHarmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.69.4010
ECCN CodeECCN CodeExport Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
RoHS StatusRoHS StatusIndicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
Not applicable
Moisture Sensitivity Level (MSL)Moisture Sensitivity Level (MSL)Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
1 (Unlimited)
Product Parameter1 parameters⌄
Frequency (Max)Frequency (Max)Maximum operating frequency specifies the highest clock or switching rate at which the component reliably functions. Designers verify this limit against their application's timing budget to avoid signal integrity issues and ensure stable operation over temperature and voltage variations.
11GHz
Technical document
1-1478224-0 — Datasheet
Open the manufacturer document for package drawings and electrical specifications.
Review the cancellation and claim conditions for your quoted lot before confirming an order.
Standard-stock cancellation may be requested before packing or shipment release. Backorder, shortage and committed channel-sourced material may be NCNR once supply is locked.
Returns require prior written authorization and an RMA reference. Non-quality returns are generally not accepted for confirmed special or NCNR orders.
Report quality issues promptly with the order reference, affected quantity, photos and issue description. Keep original labels and packaging for review.