TrustCompo Website Logo | TrustCompo

TE Connectivity / Signal Relays, Up to 2 Amps

19022C2U0

RELAY GEN PURPOSE DPDT 2A 24VDC

Quote this part ↓
19022C2U0 — default product illustration
Illustrative product image. Request actual-lot photos to review markings and packaging.

Part identification

Manufacturer
TE Connectivity
Series
190
View inventory & condition↓Open Datasheet

Order & pricing

Price & availability

Supply subject to market enquiry. No confirmed stock is currently available.

Reference price / piece
Price on request

We reply within 24 hours.

Technical parameters

Detailed specifications

Open Datasheet ↗
Product Attribute57 parameters
Max Voltage Rating (DC)Max Voltage Rating (DC)Specifies the maximum continuous direct current voltage the component can safely withstand. Engineers compare this rating to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet for derating guidelines and environmental conditions.
125V
Throw ConfigurationThrow ConfigurationSpecifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.
DPDT
Operating TemperatureOperating TemperatureSpecifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-40°C~70°C
Coil/Input Supply TypeCoil/Input Supply TypeSpecifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.
DC
WidthWidthPhysical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.
10.1mm
Body Length or DiameterBody Length or DiameterSpecifies the physical size of the component body, either its length for rectangular parts or diameter for cylindrical ones. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure clearance and proper mounting in your enclosure or assembly.
20.5mm
Max Current RatingMax Current RatingSpecifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits.
2A
Lead FreeLead FreeIndicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.
Lead Free
Contact Current (DC) MaxContact Current (DC) MaxSpecifies the highest continuous direct current the contact can safely carry without overheating or degrading. Compare this rating with your circuit's expected load, and verify it against the datasheet for derating curves and ambient temperature conditions.
2A
CategoriesCategoriesLists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Relays
Must Release VoltageMust Release VoltageSpecifies the voltage at which a relay is guaranteed to de-energize and return to its unoperated state. This value is critical for circuit design and ensuring reliable switching. Verify it against the datasheet to match your control signal and avoid unintended relay operation.
1.2VDC
Relay ActionRelay ActionSpecifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.
LATCHED
Dielectric Strength Between Open ContactsDielectric Strength Between Open ContactsIndicates the maximum voltage that can be applied across open contacts without causing an arc or breakdown. Critical for relay and switch isolation ratings. Verify against datasheet for safety margins in your application.
750 Vrms
Switching VoltageSwitching VoltageSpecifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.
125VAC 125VDC -Max
Contact Current (AC) - MaxContact Current (AC) - MaxSpecifies the highest alternating current the contacts can safely carry under normal operating conditions. Compare this value with your circuit's expected AC load to ensure reliable switching and avoid overheating. Always verify against the datasheet for derating factors and temperature limits.
2A
Coil TypeCoil TypeSpecifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.
Non Latching
Voltage - Rated DCVoltage - Rated DCSpecifies the maximum DC voltage the component can safely handle under rated conditions. Engineers compare this to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet's derating curves for temperature and reliability.
24V
Mounting TypeMounting TypeSpecifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
PCB, Through Hole
Operate TimeOperate TimeOperate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.
7ms
Physical DimensionPhysical DimensionOverall dimensions of the component, including length, width, and height. Essential for PCB layout and enclosure design. Confirm these measurements against the datasheet to ensure proper fit and clearance in your assembly.
20.5mm x 10.1mm x 11.5mm
Coil PowerCoil PowerPower consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.
500mW
Contact MaterialContact MaterialSpecifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.
Silver (Ag), Gold (Au)
Input Switching Control TypeInput Switching Control TypeSpecifies the method used to control input switching, such as AC, DC, or pulse. This determines how the device is triggered and affects compatibility with your control signal. Verify the required control type against your application's drive circuit and the datasheet specifications.
Random
Contact ResistanceContact ResistanceContact resistance measures the electrical resistance at the interface between mating contacts. Lower values indicate better conductivity and less heat generation. Compare this parameter across connectors, relays, and switches to ensure reliable signal integrity and power transfer. Always verify against the datasheet for your specific application.
50mOhm
Sub-CategoriesSub-CategoriesIndicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Signal Relays, Up to 2 Amps
Must Operate VoltageMust Operate VoltageDefines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.
18VDC
Coil CurrentCoil CurrentSpecifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.
20.8mA
PCB Hole CountPCB Hole CountTotal number of drilled holes in the PCB footprint for through-hole mounting or connector pins. Compare this count with your assembly drawing to ensure the board layout matches the component's mechanical dimensions and pin pattern.
8
SeriesSeriesIndicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
190
Contact/Output Supply TypeContact/Output Supply TypeSpecifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.
AC/DC
Termination StyleTermination StyleIndicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.
PC Pin
HeightHeightPhysical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.
11.5mm
PublishedPublishedPublished indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2003
Number of PinsNumber of PinsTotal number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.
8
Mounting TypeMounting TypeSpecifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Through Hole
Current RatingCurrent RatingSpecifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations.
2A
TerminationTerminationDescribes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.
PC Pin
Length - TerminationLength - TerminationLength of the termination or lead on components like resistors, capacitors, or connectors, affecting solder joint reliability and mechanical fit. This dimension is crucial for through-hole and surface-mount parts. Ensure the termination length matches your PCB hole depth or pad size. Verify the exact length in the datasheet for proper assembly.
0.0035 inch
Number of TerminationsNumber of TerminationsIndicates the total number of electrical connection points on the component, such as pins or pads. This is critical for PCB footprint design and assembly. Verify it matches the package specification to ensure proper soldering and connectivity.
8
Insulation ResistanceInsulation ResistanceIndicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
1000000000Ohm
Reference StandardReference StandardIndicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.
CSA; UL
Max Voltage Rating (AC)Max Voltage Rating (AC)Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.
125V
Relay TypeRelay TypeClassifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.
General Purpose
ManufacturerManufacturerIdentifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
PackagingPackagingIndicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.
Tube
REACH StatusREACH StatusShows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.
REACH Unaffected
Coil Voltage (DC)Coil Voltage (DC)Specifies the nominal DC voltage required to energize the relay coil. Verify this matches your control circuit supply to ensure reliable switching. Check the datasheet for allowable tolerance and minimum pickup voltage.
24V
Coil ResistanceCoil ResistanceSpecifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.
1.15kOhm
Release TimeRelease TimeRelease time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.
3ms
ECCNECCNExport Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Manufacturer's Part No.Manufacturer's Part No.The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
19022C2U0
SealingSealingIndicates the method used to protect the component from moisture, dust, and other environmental contaminants. Compare sealing types when operating conditions are harsh. Verify the specific sealing standard or rating in the datasheet to ensure reliability in your application.
PLASTIC SEALED
Part StatusPart StatusLifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Obsolete
Contact FormContact FormSpecifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.
DPDT (2 Form C)
Seal RatingSeal RatingIndicates the enclosure's protection level against gases, moisture, and contaminants. Compare ratings like IP or NEMA to ensure the component suits your operating environment. Verify the exact rating in the datasheet for reliable performance.
Sealed - Fully
Dielectric Strength Between Coil and ContactsDielectric Strength Between Coil and ContactsThis is the maximum voltage that can be applied between the relay coil and its contacts without causing insulation breakdown. It ensures safe isolation between control and switching circuits. Verify this rating against the datasheet for your application's voltage requirements.
1000 Vrms
Coil VoltageCoil VoltageSpecifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.
24VDC
Export Classifications & Environmental4 parameters
HTSUSHTSUSHarmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.41.0020
ECCN CodeECCN CodeExport Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
RoHS StatusRoHS StatusIndicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS Compliant
Moisture Sensitivity Level (MSL)Moisture Sensitivity Level (MSL)Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
1 (Unlimited)

Technical document

19022C2U0 — Datasheet

Open the manufacturer document for package drawings and electrical specifications.

Open Datasheet

Check the lot

Photos, traceability & inspection

Confirm what is available for the quoted lot, and agree any extra inspection or document requirements before purchase.

Markings & packaging

Request actual-lot photos, top markings, manufacturer labels and reel, tray or tube details. Reference images are not evidence of a specific lot.

Documents & traceability

Tell us whether you need a CoC, traceability records or compliance documents. Availability must be confirmed for the selected source and lot.

Inspection & testing

Agree the inspection scope, test reports, timing and any charges during quotation. Share customer acceptance requirements before the order is locked.

Quality controls →

Plan your purchase

Payment, delivery & documents

Review how the order will be paid, packed and shipped before committing your purchase.

Packing & delivery

Most orders ship from Hong Kong. DHL, FedEx, UPS and SF International can be arranged according to destination and service availability.

DHLFedExUPS
  • For our own stock, we dispatch on the same day or the next day after confirming the shipping method with you.
  • Prefer your own logistics? Ask for pickup or handover to your designated forwarder; confirm carrier-account or label arrangements before booking.
  • Agree freight, insurance, duties, taxes and delivery responsibilities in the quotation. DDP requests are reviewed separately.
  • International express transit is typically 3–7 business days after carrier handover. This is guidance, not a dispatch or arrival guarantee.
  • Payment confirmation, inspection, photo approval, export documents and carrier booking affect release. Share ESD, moisture protection, label and packing requirements early.
Read full terms →
Payment & invoices

Quotes are in USD. T/T bank transfer is a standard payment option; other channels depend on the order and destination.

  • PI and commercial invoices can be provided for approved orders. Confirm the payee, currency, amount and payment terms on the order documents.
  • PayPal and other channels may be available subject to regional, banking and order conditions. Credit terms require application and approval.
  • Quotes exclude tax unless stated in writing. Confirm payment charges, freight and destination costs during quote review.
Read full terms →
Returns & order changes

Review the cancellation and claim conditions for your quoted lot before confirming an order.

  • Standard-stock cancellation may be requested before packing or shipment release. Backorder, shortage and committed channel-sourced material may be NCNR once supply is locked.
  • Returns require prior written authorization and an RMA reference. Non-quality returns are generally not accepted for confirmed special or NCNR orders.
  • Report quality issues promptly with the order reference, affected quantity, photos and issue description. Keep original labels and packaging for review.
Read full terms →

Order & pricing

Ready to discuss 19022C2U0?

Your part, selected lot and quantity go with the enquiry. Add destination, delivery target and any photo, testing or EUU requirements.

Minimum order: 1 pieces

We reply within 24 hours.