TrustCompo Website Logo | TrustCompo

TE Connectivity / Coaxial Connectors (RF)

1052075-1

CONN SMA PLUG R/A 50 OHM SOLDER

Quote this part ↓
1052075-1 — default product illustration
Illustrative product image. Request actual-lot photos to review markings and packaging.

Part identification

Manufacturer
TE Connectivity
Package / case
SMA
View inventory & condition↓Open Datasheet

Order & pricing

Price & availability

Supply subject to market enquiry. No confirmed stock is currently available.

Reference price / piece
Price on request

We reply within 24 hours.

Technical parameters

Detailed specifications

Open Datasheet ↗
Product Attribute54 parameters
Contact MaterialContact MaterialSpecifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.
Copper
Insulation ResistanceInsulation ResistanceIndicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
10GOhm
ManufacturerManufacturerIdentifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
Voltage - RatedVoltage - RatedSpecifies the maximum continuous voltage the component can safely withstand under normal operating conditions. Engineers compare this rating to the circuit's expected voltage to ensure reliable operation. Always verify against the datasheet for derating factors and environmental conditions.
250V
IEC ConformanceIEC ConformanceIndicates whether the component meets International Electrotechnical Commission standards. Check this attribute to ensure compatibility with international safety and performance requirements. Verify the specific IEC standard listed in the datasheet for your application.
NO
ImpedanceImpedanceSpecifies the opposition to alternating current in a component, typically for RF or high-speed signal paths. Compare values to ensure proper impedance matching and signal integrity. Verify against the datasheet for your application frequency.
50Ohm
Radiation HardeningRadiation HardeningIndicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet.
No
Manufacturer's Part No.Manufacturer's Part No.The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
1052075-1
IncludesIncludesSpecifies accessories or parts supplied with the component. Check this field to confirm what is included in the package, such as connectors, mounting hardware, or cables. Verify against the datasheet or packaging list to ensure you have all necessary items for your application.
4 pcs - 1 Connector, 1 End Cap, 1 Ferrule, 1 Heat Shrink
Lead FreeLead FreeIndicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.
Not Applicable
Sub-CategoriesSub-CategoriesIndicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Coaxial Connectors (RF)
Fastening TypeFastening TypeSpecifies the mechanical method used to secure the component to a PCB or panel, such as screw, snap-in, or adhesive. This affects assembly time, reliability under vibration, and serviceability. Verify compatibility with your mounting process and enclosure design before ordering.
Threaded
Contact StyleContact StyleSpecifies the physical shape or configuration of the electrical contact, such as pin, socket, blade, or crimp. This affects mating compatibility and reliability. Verify the contact style against the connector series and datasheet to ensure proper fit and performance in your application.
COAX
Body MaterialBody MaterialDefines the insulating material of the connector body, impacting mechanical strength, temperature rating, and flammability. Essential for environmental compliance and durability. Confirm material grade and UL rating in the datasheet before design-in.
Stainless Steel
DIN ConformanceDIN ConformanceIndicates whether the component complies with German DIN standards. Verify this attribute when the application requires specific mechanical, electrical, or safety specifications defined by DIN. Check the datasheet for the exact DIN number and edition to ensure compatibility with your system.
NO
CategoriesCategoriesLists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Connectors, Interconnects
DepthDepthPhysical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.
7.9mm
FrequencyFrequencyOperating frequency of the component, typically the clock or switching frequency. This determines the speed of operation and affects power dissipation and signal integrity. Verify the frequency range against your application's requirements and the datasheet specifications.
12.4Hz
Connector TypeConnector TypeSpecifies the connector series or family, such as USB, RJ45, or D-Sub. This determines mechanical compatibility, pin layout, and mating standards. Verify against the datasheet to ensure the connector matches your board design and mating counterpart.
Plug, Male Pin
Filter FeatureFilter FeatureSpecifies the type of filtering the component provides, such as EMI, RFI, or signal conditioning. Compare this attribute when selecting parts for noise suppression or signal integrity. Verify the exact filter topology and performance against the datasheet.
NO
ECCNECCNExport Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Number of PortsNumber of PortsIndicates how many independent connection points or interfaces the component provides. Compare this when selecting connectors, switches, or modules for multi-channel designs. Verify against the datasheet to ensure the port count matches your system's required I/O configuration.
1
Center Contact MaterialCenter Contact MaterialSpecifies the conductive alloy or plating used for the center pin or contact in connectors, switches, or RF components. This affects electrical conductivity, wear resistance, and corrosion performance. Verify against datasheet for reliability in high-cycle or harsh environments.
Beryllium Copper
Cable GroupCable GroupIdentifies the category or group of cable that is compatible with the component, such as flat ribbon, twisted pair, or coaxial. This attribute helps ensure the correct cable type is selected for the connector or module. Always confirm with the datasheet for exact cable specifications.
RG-188A
GenderGenderGender indicates whether a connector is male (with pins) or female (with sockets). This is critical for mating compatibility in cable assemblies and board-to-board connections. Verify gender against the mating connector part number to ensure proper fit and reliable electrical contact.
Male
MIL ConformanceMIL ConformanceIndicates whether the component meets military specifications (MIL-SPEC) for reliability, performance, and environmental resistance. This is critical for defense, aerospace, and high-reliability applications. Verify the specific MIL standard and test conditions in the datasheet.
NO
Contact TerminationContact TerminationSpecifies how the contact is electrically and mechanically connected to the wire or PCB. Common types include solder, crimp, and press-fit. Choose based on assembly method and reliability requirements. Verify compatibility with your wire gauge or board thickness in the datasheet.
Solder
Connector StyleConnector StyleStyle or type of the connector, such as D-sub, USB, RJ45, or circular, determining its mechanical interface and electrical performance. Choose the style that matches your mating connector and application environment. Verify the connector style in the datasheet to ensure proper fit, pinout, and durability for your design.
SMA
REACH StatusREACH StatusShows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.
Vendor Undefined
SealableSealableIndicates whether the component can be sealed to protect against moisture, dust, or other environmental factors. Relevant for connectors, switches, and enclosures used in harsh environments. Verify sealing capability with the manufacturer's specifications.
Yes
Dielectric MaterialDielectric MaterialInsulating material used in capacitors, connectors, or substrates, determining electrical performance, temperature stability, and insulation resistance. Choose among ceramic, tantalum, or polymer types based on capacitance, voltage, and frequency requirements. Always confirm the dielectric specification in the datasheet for your application's operating conditions.
Polytetrafluoroethylene (PTFE)
Factory Lead TimeFactory Lead TimeIndicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
6 Weeks
Center Contact PlatingCenter Contact PlatingDefines the plating material on the center contact of coaxial connectors or similar components. This finish impacts signal integrity, wear resistance, and mating durability. Check the datasheet for recommended plating when matching connectors for high-frequency or repeated use.
Gold
OrientationOrientationIndicates the physical mounting orientation of the connector relative to the PCB or mating direction. Engineers compare this to ensure proper alignment in the assembly. Verify against the datasheet for correct placement and mating.
Right Angle
LengthLengthSpecifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.
16.891mm
Contact PlatingContact PlatingSpecifies the metal coating applied to the contact surfaces of connectors, switches, or relays. This finish affects conductivity, corrosion resistance, and durability. Engineers should verify the plating material and thickness against the datasheet to ensure reliable performance in the intended environment.
Copper, Gold
Operating TemperatureOperating TemperatureSpecifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-65°C~125°C
PackagingPackagingIndicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.
Bulk
PolarityPolaritySpecifies whether the component or signal has a defined positive and negative orientation, such as for diodes, electrolytic capacitors, or connectors. Incorrect polarity can cause failure or unsafe operation. Always check the datasheet and board markings before installation.
Normal
OptionOptionDescribes the specific configuration or variant of the component, such as packaging, lead form, or mounting style. Engineers compare options to match exact design requirements. Always check the option code against the datasheet to ensure compatibility with your application.
GENERAL PURPOSE
Insertion LossInsertion LossInsertion loss measures signal power reduction caused by placing a component in a transmission path. Lower values indicate better performance. Compare this parameter across similar components to ensure signal integrity in your application, and verify it against the datasheet for your operating frequency.
0.07 dB
Insulation MaterialInsulation MaterialSpecifies the dielectric material used to isolate conductive parts in components such as transformers, connectors, or cables. This affects thermal resistance, voltage withstand capability, and flammability rating. Verify the material against datasheet specifications for safety and performance in your application.
Tetrafluoroethylene
Mating CyclesMating CyclesIndicates the number of times a connector can be mated and unmated before performance degrades. Compare this rating when selecting connectors for frequent disconnection applications. Verify against the datasheet to ensure durability matches your expected usage.
500
Contact ResistanceContact ResistanceContact resistance measures the electrical resistance at the interface between mating contacts. Lower values indicate better conductivity and less heat generation. Compare this parameter across connectors, relays, and switches to ensure reliable signal integrity and power transfer. Always verify against the datasheet for your specific application.
3mOhm
Lifecycle StatusLifecycle StatusCurrent stage in the product's lifecycle, such as Active, Obsolete, or End of Life. This indicates availability and long-term supply risk. Check this before designing in a part to ensure it will be available for your product's production lifetime.
ACTIVE (Last Updated: 4 days ago)
ReliabilityReliabilityReliability rating or qualification indicates the component's expected performance under specified conditions over time. Compare reliability levels when selecting parts for critical applications, and verify the qualification standard against the datasheet to ensure it meets your requirements.
COMMERCIAL
Part StatusPart StatusLifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
ELV ComplianceELV ComplianceIndicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.
Compliant
Mounting TypeMounting TypeSpecifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Free Hanging (In-Line), Right Angle
Shield TerminationShield TerminationIndicates how the cable shield is terminated, such as soldered, crimped, or clamped. This affects grounding effectiveness and EMI performance. Verify the method against the datasheet to ensure proper shielding and signal integrity in your application.
Crimp
Total Number of ContactsTotal Number of ContactsSpecifies the total number of electrical contact points in the connector. This determines the maximum number of circuits that can be connected. Verify against the datasheet to ensure it matches your required pin count and mating connector configuration.
1
PublishedPublishedPublished indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2009
Mounting TypeMounting TypeSpecifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
Cable, Free Hanging, Through Hole
Number of PositionsNumber of PositionsTotal number of contact positions in the connector. This determines the maximum number of electrical connections possible. Compare with your circuit requirements and verify against the datasheet to ensure the connector matches your pin count and layout.
1
Export Classifications & Environmental4 parameters
RoHS StatusRoHS StatusIndicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS Compliant
Moisture Sensitivity Level (MSL)Moisture Sensitivity Level (MSL)Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
1 (Unlimited)
HTSUSHTSUSHarmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.69.4010
ECCN CodeECCN CodeExport Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99

Technical document

1052075-1 — Datasheet

Open the manufacturer document for package drawings and electrical specifications.

Open Datasheet

Check the lot

Photos, traceability & inspection

Confirm what is available for the quoted lot, and agree any extra inspection or document requirements before purchase.

Markings & packaging

Request actual-lot photos, top markings, manufacturer labels and reel, tray or tube details. Reference images are not evidence of a specific lot.

Documents & traceability

Tell us whether you need a CoC, traceability records or compliance documents. Availability must be confirmed for the selected source and lot.

Inspection & testing

Agree the inspection scope, test reports, timing and any charges during quotation. Share customer acceptance requirements before the order is locked.

Quality controls →

Plan your purchase

Payment, delivery & documents

Review how the order will be paid, packed and shipped before committing your purchase.

Packing & delivery

Most orders ship from Hong Kong. DHL, FedEx, UPS and SF International can be arranged according to destination and service availability.

DHLFedExUPS
  • For our own stock, we dispatch on the same day or the next day after confirming the shipping method with you.
  • Prefer your own logistics? Ask for pickup or handover to your designated forwarder; confirm carrier-account or label arrangements before booking.
  • Agree freight, insurance, duties, taxes and delivery responsibilities in the quotation. DDP requests are reviewed separately.
  • International express transit is typically 3–7 business days after carrier handover. This is guidance, not a dispatch or arrival guarantee.
  • Payment confirmation, inspection, photo approval, export documents and carrier booking affect release. Share ESD, moisture protection, label and packing requirements early.
Read full terms →
Payment & invoices

Quotes are in USD. T/T bank transfer is a standard payment option; other channels depend on the order and destination.

  • PI and commercial invoices can be provided for approved orders. Confirm the payee, currency, amount and payment terms on the order documents.
  • PayPal and other channels may be available subject to regional, banking and order conditions. Credit terms require application and approval.
  • Quotes exclude tax unless stated in writing. Confirm payment charges, freight and destination costs during quote review.
Read full terms →
Returns & order changes

Review the cancellation and claim conditions for your quoted lot before confirming an order.

  • Standard-stock cancellation may be requested before packing or shipment release. Backorder, shortage and committed channel-sourced material may be NCNR once supply is locked.
  • Returns require prior written authorization and an RMA reference. Non-quality returns are generally not accepted for confirmed special or NCNR orders.
  • Report quality issues promptly with the order reference, affected quantity, photos and issue description. Keep original labels and packaging for review.
Read full terms →

Order & pricing

Ready to discuss 1052075-1?

Your part, selected lot and quantity go with the enquiry. Add destination, delivery target and any photo, testing or EUU requirements.

Minimum order: 1 pieces

We reply within 24 hours.