TrustCompo Website Logo | TrustCompo

TE Connectivity / Coaxial Connectors (RF)

225532-9

CONN SMA PLUG STR 50 OHM CRIMP

Quote this part ↓
225532-9 — default product illustration
Illustrative product image. Request actual-lot photos to review markings and packaging.

Part identification

Manufacturer
TE Connectivity
Package / case
SMA
Series
Military, MIL-PRF-39012
View inventory & condition↓Open Datasheet

Order & pricing

Price & availability

Supply subject to market enquiry. No confirmed stock is currently available.

Reference price / piece
Price on request

We reply within 24 hours.

Technical parameters

Detailed specifications

Open Datasheet ↗
Product Attribute53 parameters
Operating Frequency-MaxOperating Frequency-MaxSpecifies the highest frequency at which the component reliably meets its electrical specifications. Compare this value with your application's signal frequency to ensure proper performance. Always verify against the datasheet for derating or environmental conditions.
12.4GHz
Part StatusPart StatusLifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Discontinued
Maximum Insertion ForceMaximum Insertion ForceMaximum force needed to fully mate a connector pair. Critical for manual assembly ergonomics and automated production tooling. Verify against datasheet to ensure compatibility with your application's insertion equipment and operator comfort.
13.344 N
Sub-CategoriesSub-CategoriesIndicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Coaxial Connectors (RF)
Operating Temperature (Min)Operating Temperature (Min)Specifies the lowest ambient temperature at which the component remains fully functional. Check this limit against your application's environmental extremes to ensure reliable operation. Exceeding this minimum may cause performance degradation or failure, so always verify with the datasheet.
-65°C
OptionOptionDescribes the specific configuration or variant of the component, such as packaging, lead form, or mounting style. Engineers compare options to match exact design requirements. Always check the option code against the datasheet to ensure compatibility with your application.
GENERAL PURPOSE
GenderGenderGender indicates whether a connector is male (with pins) or female (with sockets). This is critical for mating compatibility in cable assemblies and board-to-board connections. Verify gender against the mating connector part number to ensure proper fit and reliable electrical contact.
Male
Mating InformationMating InformationSpecifies the mating connector or counterpart part required for proper connection. Use this to verify compatibility with your existing system or to order the correct mating component. Always cross-check with the datasheet for exact part numbers and locking mechanisms.
MULTIPLE MATING PARTS AVAILABLE
ImpedanceImpedanceSpecifies the opposition to alternating current in a component, typically for RF or high-speed signal paths. Compare values to ensure proper impedance matching and signal integrity. Verify against the datasheet for your application frequency.
50Ohm
Package / CasePackage / CasePhysical package or case type of the component, defining its dimensions, mounting style, and thermal characteristics. Common types include SMD, through-hole, BGA, and QFN. Choose the package that fits your PCB layout and assembly process. Verify the exact package code in the datasheet for footprint compatibility.
SMA
PolarityPolaritySpecifies whether the component or signal has a defined positive and negative orientation, such as for diodes, electrolytic capacitors, or connectors. Incorrect polarity can cause failure or unsafe operation. Always check the datasheet and board markings before installation.
Standard
Radiation HardeningRadiation HardeningIndicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet.
No
Body DepthBody DepthMeasures the physical depth of the connector body from front to back, excluding any mounting hardware or contacts. This dimension is critical for ensuring proper clearance in enclosures and mating with other components. Verify against the datasheet for exact tolerances and mounting considerations.
1.188 inch
PublishedPublishedPublished indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2012
Fastening TypeFastening TypeSpecifies the mechanical method used to secure the component to a PCB or panel, such as screw, snap-in, or adhesive. This affects assembly time, reliability under vibration, and serviceability. Verify compatibility with your mounting process and enclosure design before ordering.
Threaded
Contact StyleContact StyleSpecifies the physical shape or configuration of the electrical contact, such as pin, socket, blade, or crimp. This affects mating compatibility and reliability. Verify the contact style against the connector series and datasheet to ensure proper fit and performance in your application.
COAX
Insertion LossInsertion LossInsertion loss measures signal power reduction caused by placing a component in a transmission path. Lower values indicate better performance. Compare this parameter across similar components to ensure signal integrity in your application, and verify it against the datasheet for your operating frequency.
0.21 dB
Insulation MaterialInsulation MaterialSpecifies the dielectric material used to isolate conductive parts in components such as transformers, connectors, or cables. This affects thermal resistance, voltage withstand capability, and flammability rating. Verify the material against datasheet specifications for safety and performance in your application.
Teflon
Connector TypeConnector TypeSpecifies the connector series or family, such as USB, RJ45, or D-Sub. This determines mechanical compatibility, pin layout, and mating standards. Verify against the datasheet to ensure the connector matches your board design and mating counterpart.
Plug, SMA
Withdrawal Force MinWithdrawal Force MinMinimum force required to withdraw a connector from its mating part. Ensures reliable mechanical retention and prevents accidental disconnection. Engineers compare this for applications with vibration or shock. Check datasheet for test conditions.
.278 N
DurabilityDurabilityIndicates the number of mating cycles a connector can endure before electrical or mechanical failure. Compare this value when selecting connectors for frequent insertion and removal. Verify the rated cycles in the datasheet to ensure long-term reliability in your application.
500 Cycles
Mounting TypeMounting TypeSpecifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
Cable, Free Hanging
IEC ConformanceIEC ConformanceIndicates whether the component meets International Electrotechnical Commission standards. Check this attribute to ensure compatibility with international safety and performance requirements. Verify the specific IEC standard listed in the datasheet for your application.
NO
ManufacturerManufacturerIdentifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
TE Connectivity
ECCNECCNExport Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.
EAR99
Body PlatingBody PlatingSpecifies the metallic coating applied to the component body, affecting solderability, corrosion resistance, and appearance. Compare plating types for environmental compliance and reliability. Verify the exact material and thickness in the datasheet for your application.
Passivated
SeriesSeriesIndicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
Military, MIL-PRF-39012
Dielectric MaterialDielectric MaterialInsulating material used in capacitors, connectors, or substrates, determining electrical performance, temperature stability, and insulation resistance. Choose among ceramic, tantalum, or polymer types based on capacitance, voltage, and frequency requirements. Always confirm the dielectric specification in the datasheet for your application's operating conditions.
Fluoropolymer
Lead FreeLead FreeIndicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.
Not Applicable
Filter FeatureFilter FeatureSpecifies the type of filtering the component provides, such as EMI, RFI, or signal conditioning. Compare this attribute when selecting parts for noise suppression or signal integrity. Verify the exact filter topology and performance against the datasheet.
NO
HTS CodeHTS CodeHarmonized Tariff Schedule code used for customs classification of electronic components. Helps determine duties and regulatory requirements. Buyers should confirm the code with a customs broker for accurate shipping.
8536.69.40.10
DIN ConformanceDIN ConformanceIndicates whether the component complies with German DIN standards. Verify this attribute when the application requires specific mechanical, electrical, or safety specifications defined by DIN. Check the datasheet for the exact DIN number and edition to ensure compatibility with your system.
NO
ELV ComplianceELV ComplianceIndicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.
Non-Compliant
TerminationTerminationDescribes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.
Crimp
Contact ResistanceContact ResistanceContact resistance measures the electrical resistance at the interface between mating contacts. Lower values indicate better conductivity and less heat generation. Compare this parameter across connectors, relays, and switches to ensure reliable signal integrity and power transfer. Always verify against the datasheet for your specific application.
4mOhm
LengthLengthSpecifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.
26.17mm
Manufacturer's Part No.Manufacturer's Part No.The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
225532-9
OrientationOrientationIndicates the physical mounting orientation of the connector relative to the PCB or mating direction. Engineers compare this to ensure proper alignment in the assembly. Verify against the datasheet for correct placement and mating.
Straight
Pb-Free CodePb-Free CodeIndicates whether the component is lead-free per RoHS or other directives. Buyers use this to verify environmental compliance and avoid restricted substances. Always confirm with the datasheet or certificate of compliance.
no
Polarization KeyPolarization KeyA physical feature on connectors or housings that ensures correct mating orientation. This prevents mismating and potential damage. Verify the key type and position against the datasheet to ensure compatibility with your mating connector and application.
POLARIZED HOUSING
CategoriesCategoriesLists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Connectors, Interconnects
Dielectric Withstanding VoltageDielectric Withstanding VoltageSpecifies the maximum voltage that the insulation between conductors can withstand without breakdown. Critical for safety and reliability in power supplies, transformers, and connectors. Engineers must verify this rating against the datasheet for their application's isolation requirements.
1400VAC V
Number of PortsNumber of PortsIndicates how many independent connection points or interfaces the component provides. Compare this when selecting connectors, switches, or modules for multi-channel designs. Verify against the datasheet to ensure the port count matches your system's required I/O configuration.
1
Body MaterialBody MaterialDefines the insulating material of the connector body, impacting mechanical strength, temperature rating, and flammability. Essential for environmental compliance and durability. Confirm material grade and UL rating in the datasheet before design-in.
Stainless Steel
Cable TypeCable TypeSelect the cable construction that matches your application, such as coaxial, ribbon, or twisted pair. This determines signal integrity, flexibility, and shielding. Verify the exact type against the datasheet to ensure compatibility with connectors and environmental requirements.
RG-141
Contact MaterialContact MaterialSpecifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.
Brass
VSWRVSWRVoltage standing wave ratio indicates how well the component's impedance matches its transmission line. Lower values mean better matching and less signal reflection. Compare VSWR across similar parts to ensure efficient power transfer in RF systems, and verify against the datasheet for your operating frequency.
1.15
ReliabilityReliabilityReliability rating or qualification indicates the component's expected performance under specified conditions over time. Compare reliability levels when selecting parts for critical applications, and verify the qualification standard against the datasheet to ensure it meets your requirements.
COMMERCIAL
MIL ConformanceMIL ConformanceIndicates whether the component meets military specifications (MIL-SPEC) for reliability, performance, and environmental resistance. This is critical for defense, aerospace, and high-reliability applications. Verify the specific MIL standard and test conditions in the datasheet.
YES
Contact PlatingContact PlatingSpecifies the metal coating applied to the contact surfaces of connectors, switches, or relays. This finish affects conductivity, corrosion resistance, and durability. Engineers should verify the plating material and thickness against the datasheet to ensure reliable performance in the intended environment.
Gold
Operating Temperature (Max)Operating Temperature (Max)Specifies the highest ambient temperature at which the component can operate reliably. Check this limit against your application's thermal environment to prevent overheating and ensure long-term stability. Always verify with the datasheet for derating curves.
165°C
Insulation ResistanceInsulation ResistanceIndicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
5000000000Ohm
Total Number of ContactsTotal Number of ContactsSpecifies the total number of electrical contact points in the connector. This determines the maximum number of circuits that can be connected. Verify against the datasheet to ensure it matches your required pin count and mating connector configuration.
1
Export Classifications & Environmental5 parameters
Moisture Sensitivity Level (MSL)Moisture Sensitivity Level (MSL)Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
Not Applicable
HTSUSHTSUSHarmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.
8536.69.4010
ECCN CodeECCN CodeExport Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
RoHS StatusRoHS StatusIndicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS non-compliant
JESD-609 CodeJESD-609 CodeThis code indicates the terminal finish material per JESD-609 standard. It helps identify the plating type for soldering compatibility and environmental compliance. Check the datasheet for the exact code and its meaning.
e4

Technical document

225532-9 — Datasheet

Open the manufacturer document for package drawings and electrical specifications.

Open Datasheet

Check the lot

Photos, traceability & inspection

Confirm what is available for the quoted lot, and agree any extra inspection or document requirements before purchase.

Markings & packaging

Request actual-lot photos, top markings, manufacturer labels and reel, tray or tube details. Reference images are not evidence of a specific lot.

Documents & traceability

Tell us whether you need a CoC, traceability records or compliance documents. Availability must be confirmed for the selected source and lot.

Inspection & testing

Agree the inspection scope, test reports, timing and any charges during quotation. Share customer acceptance requirements before the order is locked.

Quality controls →

Plan your purchase

Payment, delivery & documents

Review how the order will be paid, packed and shipped before committing your purchase.

Packing & delivery

Most orders ship from Hong Kong. DHL, FedEx, UPS and SF International can be arranged according to destination and service availability.

DHLFedExUPS
  • For our own stock, we dispatch on the same day or the next day after confirming the shipping method with you.
  • Prefer your own logistics? Ask for pickup or handover to your designated forwarder; confirm carrier-account or label arrangements before booking.
  • Agree freight, insurance, duties, taxes and delivery responsibilities in the quotation. DDP requests are reviewed separately.
  • International express transit is typically 3–7 business days after carrier handover. This is guidance, not a dispatch or arrival guarantee.
  • Payment confirmation, inspection, photo approval, export documents and carrier booking affect release. Share ESD, moisture protection, label and packing requirements early.
Read full terms →
Payment & invoices

Quotes are in USD. T/T bank transfer is a standard payment option; other channels depend on the order and destination.

  • PI and commercial invoices can be provided for approved orders. Confirm the payee, currency, amount and payment terms on the order documents.
  • PayPal and other channels may be available subject to regional, banking and order conditions. Credit terms require application and approval.
  • Quotes exclude tax unless stated in writing. Confirm payment charges, freight and destination costs during quote review.
Read full terms →
Returns & order changes

Review the cancellation and claim conditions for your quoted lot before confirming an order.

  • Standard-stock cancellation may be requested before packing or shipment release. Backorder, shortage and committed channel-sourced material may be NCNR once supply is locked.
  • Returns require prior written authorization and an RMA reference. Non-quality returns are generally not accepted for confirmed special or NCNR orders.
  • Report quality issues promptly with the order reference, affected quantity, photos and issue description. Keep original labels and packaging for review.
Read full terms →

Order & pricing

Ready to discuss 225532-9?

Your part, selected lot and quantity go with the enquiry. Add destination, delivery target and any photo, testing or EUU requirements.

Minimum order: 1 pieces

We reply within 24 hours.