TrustCompo Website Logo | TrustCompo

3-1462039-2 Signal Relays, Up to 2 Amps by TE Connectivity

3-1462039-2 is a Signal Relays, Up to 2 Amps from TE Connectivity in DIP packaging. It is commonly reviewed for RELAY TELECOM DPDT 2A 12VDC. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.

Pictures are for reference only. Please contact us for the latest pictures.

3-1462039-2 Signal Relays, Up to 2 Amps by TE Connectivity | TrustCompo
Pictures are for reference only. Please contact us for the latest pictures.
  • 365-Day GuaranteeAfter-sales support helps buyers handle quality questions with a clearer return and review window.
  • Ships within 24-48 HoursAvailable items can move quickly once the quote, quantity, and delivery details are confirmed.
  • 100% Anti-Counterfeit TestedParts are checked through authenticity-focused handling and inspection before shipment.

Key specifications

Part Number

3-1462039-2

Internal code

TCE000078928

Package

DIP

Manufacturer
TE Connectivity

Key specifications

Series

IM, AXICOM

Min Quantity

1

Category
Relays
Description

RELAY TELECOM DPDT 2A 12VDC

key Attributes

-

Trust signals

Quality and trust signals

Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.

4 certifications
  • ISO 9001

    Quality management processes for more consistent sourcing and handling.

  • AS9120B

    Aerospace-focused distribution controls for traceability and reliability.

  • ISO 14001

    Environmental management discipline across warehouse and operating workflows.

  • ESD Control

    Electrostatic handling standards to help protect sensitive components.

RFQ checklist

Order process

Confirm the core buying details for 3-1462039-2 before RFQ, PO release, and shipment planning.

  1. 1

    Confirm MPN

    Use the exact part number, manufacturer, package, and approval constraints in the RFQ.

  2. 2

    Check stock and price

    Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.

  3. 3

    Align documents

    Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.

  4. 4

    Arrange shipment

    Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.

Before PO release

Part confirmation

  • Exact MPN confirmed: 3-1462039-2
  • Package to verify: DIP

Commercial confirmation

  • Live stock and lead time confirmed by RFQ
  • Final price and tax terms confirmed before PO release

Fulfillment & documents

  • Ship-from location: Hong Kong warehouse
  • Shipping method: DHL, FedEx, UPS, or buyer forwarder account

Technical parameters

Parameters

Compare grouped 3-1462039-2 parameters from TE Connectivity, including package, series, key attributes, and technical values used for engineering and sourcing review.

  • Product Attribute

    Part Status

    Active

  • Product Attribute

    Manufacturer

    TE Connectivity

  • Product Attribute

    Mounting Type

    Through Hole

  • Product Attribute

    ELV Compliance

    Compliant

  • Product Attribute

    Published

    2008

  • Product Attribute

    REACH Status

    REACH Unaffected

3-1462039-2 Product Attribute
ParameterValue
Part Status

Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.

Active
Manufacturer

Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.

TE Connectivity
Mounting Type

Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.

Through Hole
ELV Compliance

Indicates compliance with the European End-of-Life Vehicle directive, restricting hazardous substances in automotive components. Verify this attribute when sourcing parts for vehicles to ensure environmental and regulatory compliance. Check the datasheet or certificate for specific ELV status.

Compliant
Published

Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.

2008
REACH Status

Shows whether the component complies with the EU REACH regulation. Essential for legal market access in Europe. Check the manufacturer's latest statement to confirm that no substances of very high concern are present above the threshold.

REACH Unaffected
ECCN

Export Control Classification Number assigned by the U.S. government. Determines whether the component requires an export license. Essential for international trade compliance. Verify the ECCN with the manufacturer or supplier before shipping to avoid legal issues.

EAR99
Voltage - Rated AC

Maximum AC voltage that the component can safely withstand under specified conditions. This rating is critical for insulation and safety margins. Always compare it with the operating voltage in your circuit and derate according to the datasheet guidelines.

250V
Packaging

Indicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.

Tube
Factory Lead Time

Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.

15 Weeks
Lifecycle Status

Current stage in the product's lifecycle, such as Active, Obsolete, or End of Life. This indicates availability and long-term supply risk. Check this before designing in a part to ensure it will be available for your product's production lifetime.

ACTIVE (Last Updated: 5 days ago)
Minimum Operating Temperature

Specifies the lowest ambient temperature at which the component is guaranteed to function within its electrical and mechanical specifications. Verify this limit against the datasheet for your application's thermal environment, especially for automotive or industrial designs.

-40°C
Depth

Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.

6mm
Operating Temperature

Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.

-40°C~85°C
Max Operating Temperature

Specifies the highest ambient temperature at which the component reliably functions. Compare this limit with your application's thermal environment to ensure safe operation. Always verify against the datasheet's derating curves and test conditions, as exceeding this value may cause performance degradation or permanent damage.

85°C
Package / Case

Physical package or case type of the component, defining its dimensions, mounting style, and thermal characteristics. Common types include SMD, through-hole, BGA, and QFN. Choose the package that fits your PCB layout and assembly process. Verify the exact package code in the datasheet for footprint compatibility.

DIP
Must Release Voltage

Specifies the voltage at which a relay is guaranteed to de-energize and return to its unoperated state. This value is critical for circuit design and ensuring reliable switching. Verify it against the datasheet to match your control signal and avoid unintended relay operation.

1.2VDC
Coil Type

Specifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.

Non Latching
Coil Voltage

Specifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.

12VDC
Categories

Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.

Relays
Operate Time

Operate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.

3ms
Switching Voltage

Specifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.

250VAC 220VDC -Max
Seal Rating

Indicates the enclosure's protection level against gases, moisture, and contaminants. Compare ratings like IP or NEMA to ensure the component suits your operating environment. Verify the exact rating in the datasheet for reliable performance.

Sealed - Hermetically
Relay Type

Classifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.

Telecom
Contact Form

Specifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.

DPDT (2 Form C)
Contact Resistance

Contact resistance measures the electrical resistance at the interface between mating contacts. Lower values indicate better conductivity and less heat generation. Compare this parameter across connectors, relays, and switches to ensure reliable signal integrity and power transfer. Always verify against the datasheet for your specific application.

50mOhm
Max Voltage Rating (DC)

Specifies the maximum continuous direct current voltage the component can safely withstand. Engineers compare this rating to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet for derating guidelines and environmental conditions.

220V
Throw Configuration

Specifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.

DPDT
Series

Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.

IM, AXICOM
Sub-Categories

Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.

Signal Relays, Up to 2 Amps
Length

Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.

254mm
Termination

Describes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.

PCB
Contact Material

Specifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.

Palladium (Pd), Ruthenium (Ru), Gold (Au)
Height

Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.

5.65mm
Weight

Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.

21.262142g
Contact Plating

Specifies the metal coating applied to the contact surfaces of connectors, switches, or relays. This finish affects conductivity, corrosion resistance, and durability. Engineers should verify the plating material and thickness against the datasheet to ensure reliable performance in the intended environment.

Gold
Mounting Type

Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.

Through Hole
Number Of Pins

Total number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.

8
Current Rating

Specifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations.

2A
Max Voltage Rating (AC)

Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.

250V
Termination Style

Indicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.

PC Pin
Coil Current

Specifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.

4.2mA
Release Time

Release time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.

3ms
Switching Current

Specifies the maximum current that a switch, relay, or connector can safely make or break during operation. Compare this rating with your load current to avoid contact welding or arcing. Always verify against the datasheet for resistive and inductive loads.

2A
Max Current Rating

Specifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits.

2A
Width

Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.

6mm
Coil Voltage (DC)

Specifies the nominal DC voltage required to energize the relay coil. Verify this matches your control circuit supply to ensure reliable switching. Check the datasheet for allowable tolerance and minimum pickup voltage.

12V
Insertion Loss (DB)

Insertion loss measures signal power reduction when a component is placed in a transmission line. Lower values indicate better performance. Compare this parameter across similar parts and verify it against the datasheet for your operating frequency.

-0.03 dB
Contact Voltage Rating (DC)

Maximum DC voltage that can be safely applied across the contacts of a switch, relay, or connector. Exceeding this rating may cause arcing or insulation breakdown. Verify against datasheet for your application.

220V
Number Of Contacts

Total number of electrical contacts in the connector, which determines the maximum number of circuits that can be connected. This is a critical parameter for matching the connector to your wire harness requirements. Ensure the contact count aligns with your signal and power needs.

2
Ambient Temperature Range High

Defines the upper limit of ambient temperature for reliable operation without thermal damage or performance degradation. Ensure your system's cooling keeps the component below this threshold. Check the datasheet for derating curves and thermal resistance values.

85°C
Contact Current Rating

Specifies the maximum continuous current each contact can safely carry. Compare this rating with your application's load requirements to prevent overheating or contact degradation. Always verify against the datasheet for derating curves and ambient temperature conditions.

2A
Coil Power

Power consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.

50mW
Manufacturer'S Part No.

The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.

3-1462039-2
Coil Resistance

Specifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.

2.88kOhms
Must Operate Voltage

Defines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.

10.2VDC
3-1462039-2 Export Classifications & Environmental
ParameterValue
Moisture Sensitivity Level (MSL)

Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.

1 (Unlimited)
RoHS Status

Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.

ROHS3 Compliant
HTSUS

Harmonized Tariff Schedule of the United States code for customs classification. Essential for import/export documentation and duty calculation. Verify the correct code with a trade specialist to avoid customs delays.

8536.41.0020

Datasheet preview

Datasheet PDF viewer

Preview the 3-1462039-2 datasheet from TE Connectivity to check package, electrical characteristics, application notes, and document evidence before RFQ.

TE Connectivity

3-1462039-2

Page 1 of 0
/ —
Search within the PDF viewer.Try
Loading PDF viewer...

Notice documents

PCN / product notice documents

0 documents

No public PCN / PDN records currently displayed

No public product notice document is currently displayed for 3-1462039-2. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.

Common questions

Product FAQ

Targeted answers for buyers verifying the exact 3-1462039-2 ordering code, packaging, stock, datasheet, and replacement path.

What does 3-1462039-2 mean?

3-1462039-2 is the exact ordering code listed for a Signal Relays, Up to 2 Amps component from TE Connectivity. The current package reference is DIP, with listed context including RELAY TELECOM DPDT 2A 12VDC. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.

How should buyers verify the 3-1462039-2 ordering code?

Treat 3-1462039-2 as the full ordering code during RFQ and engineering review. Confirm the listed DIP package, manufacturer documentation from TE Connectivity, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.

What package is 3-1462039-2 supplied in?

3-1462039-2 is currently listed with package reference DIP from TE Connectivity. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.

Is 3-1462039-2 currently available?

3-1462039-2 is currently marked with stock availability on this page. Before ordering, confirm the package (DIP), listed stock (21622), available quantity (46994), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.

Where can I compare 3-1462039-2 alternatives?

A mapped alternative list is not currently published for 3-1462039-2. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.