
6ES71326HC500BU0 Controllers - PLC Modules by Siemens
6ES71326HC500BU0 is a Controllers - PLC Modules from Siemens in manufacturer-listed packaging. It is commonly reviewed for Controllers - PLC Modules. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.
Pictures are for reference only. Please contact us for the latest pictures.

- 365-Day GuaranteeAfter-sales support helps buyers handle quality questions with a clearer return and review window.
- Ships within 24-48 HoursAvailable items can move quickly once the quote, quantity, and delivery details are confirmed.
- 100% Anti-Counterfeit TestedParts are checked through authenticity-focused handling and inspection before shipment.
Key specifications
- Part Number
6ES71326HC500BU0
- Internal code
TCE000059940
- Package
-
- Manufacturer
- Siemens
Key specifications
- Series
-
- Min Quantity
1
- Category
- Industrial Automation and Controls
- Sub Category
- Controllers - PLC Modules
- Description
-
- key Attributes
-
Trust signals
Quality and trust signals
Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.
ISO 9001
Quality management processes for more consistent sourcing and handling.
AS9120B
Aerospace-focused distribution controls for traceability and reliability.
ISO 14001
Environmental management discipline across warehouse and operating workflows.
ESD Control
Electrostatic handling standards to help protect sensitive components.
RFQ checklist
Order process
Confirm the core buying details for 6ES71326HC500BU0 before RFQ, PO release, and shipment planning.
- 1
Confirm MPN
Use the exact part number, manufacturer, package, and approval constraints in the RFQ.
- 2
Check stock and price
Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.
- 3
Align documents
Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.
- 4
Arrange shipment
Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.
Before PO release
Part confirmation
- Exact MPN confirmed: 6ES71326HC500BU0
- Package to verify: -
Commercial confirmation
- Live stock and lead time confirmed by RFQ
- Final price and tax terms confirmed before PO release
Fulfillment & documents
- Ship-from location: Hong Kong warehouse
- Shipping method: DHL, FedEx, UPS, or buyer forwarder account
Technical parameters
Parameters
Compare grouped 6ES71326HC500BU0 parameters from Siemens, including package, series, key attributes, and technical values used for engineering and sourcing review.
Product Attribute
Product Status
Active
Product Attribute
PROFIsafe Protocol Support
No
Product Attribute
PROFINET CBA Protocol Support
No
Product Attribute
Gas Explosion Safety Category
None
Product Attribute
Brand
SIMATIC ET 200SP
Product Attribute
Voltage Range
-30°C ~ 60°C
| Parameter | Value |
|---|---|
Product Status Lifecycle status of the product, such as active, obsolete, or end-of-life. This affects long-term availability and design reliability. For production, choose active products to ensure supply continuity. Check the datasheet or manufacturer for lifecycle details. | Active |
PROFIsafe Protocol Support Indicates whether the device supports PROFIsafe, a safety-related communication profile for PROFIBUS and PROFINET. Verify this attribute when integrating into safety-critical systems to ensure compliance with functional safety standards and proper data exchange with safety controllers. | No |
PROFINET CBA Protocol Support Indicates whether the device supports the PROFINET CBA protocol for component-based automation. Check this attribute when integrating modules into distributed systems. Verify compatibility with your controller and network configuration against the datasheet. | No |
Gas Explosion Safety Category Indicates the gas group and temperature class for which the component is certified for explosive atmospheres. Verify this category against the datasheet to ensure the device is suitable for your hazardous area installation. | None |
Brand Manufacturer brand of the electronic component. Helps identify quality, reliability, and sourcing options. Compare brands for performance and availability. Always verify the brand matches your approved vendor list. | SIMATIC ET 200SP |
Voltage Range Defines the minimum and maximum operating voltage for the component. Essential for ensuring compatibility with your power supply and load conditions. Always check the datasheet for absolute maximum ratings and derating guidelines. | -30°C ~ 60°C |
Front Mounting Possible This attribute indicates whether the component can be mounted from the front side of the panel or PCB. It is important for assembly planning and serviceability. Verify this feature in the datasheet when designing enclosures or planning maintenance access. | No |
Foundation Fieldbus Protocol Support Indicates whether the component supports Foundation Fieldbus, a digital communication protocol for industrial automation. Check this attribute to ensure compatibility with your control system and field devices. Verify against the datasheet for protocol versions and physical layer specifications. | No |
Response Value Impedance 1 This attribute specifies the first impedance response value of the component, typically measured under defined test conditions. Compare this value with the datasheet to ensure it meets your circuit's impedance requirements, especially for filters, matching networks, or signal integrity. | DIN Rail |
Number Of Other Hardware Interfaces Specifies the count of additional hardware interfaces not covered by standard categories. Useful for comparing connectivity options across modules or boards. Verify against the datasheet to ensure the device meets your system's interface requirements. | 0 |
Number Of Industrial Ethernet Interfaces Indicates the number of physical Ethernet ports for industrial networking. Compare this when selecting controllers, switches, or gateways for factory automation. Verify against the datasheet to ensure sufficient connectivity for your fieldbus topology and network redundancy requirements. | 0 |
Output Voltage Type Specifies whether the output voltage is alternating current (AC) or direct current (DC). This attribute is critical for power supplies, converters, and modules. Verify the output type against the datasheet to ensure compatibility with your load and system requirements. | AC/DC |
GPRS Standard Indicates whether the module supports GPRS for data transmission over GSM networks. Check this attribute when selecting a cellular module for IoT or M2M applications, and verify the supported bands and data rates in the datasheet. | No |
Number Of PROFINET Interfaces Indicates how many PROFINET ports the device provides for industrial Ethernet networking. Compare this when planning network topology or daisy-chaining multiple devices. Verify against the datasheet to ensure sufficient connectivity for your automation architecture. | 0 |
PROFINET IO Protocol Support Specifies the PROFINET IO protocol variants supported by the device. Check this field to ensure compatibility with your PLC and network configuration. Verify against the datasheet for exact protocol versions and conformance classes. | No |
Number Of Parallel Hardware Interfaces Specifies how many independent hardware interface channels operate simultaneously. Compare this when selecting microcontrollers, processors, or interface ICs to ensure sufficient parallel communication paths for your design. Verify against the datasheet's interface block diagram and pinout. | 0 |
Manufacturer'S Part No. The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation. | 6ES71326HC500BU0 |
Supported KNX Protocols Specifies the KNX communication protocols implemented by the device. Verify compatibility with your building automation system's bus topology and configuration tools before integration. Essential for ensuring seamless interoperability and reliable data exchange in KNX installations. | No |
SafetyBUS P Protocol Support Indicates which SafetyBUS p protocols are supported by the device. This ensures interoperability with your safety network. Confirm the exact protocol versions and certifications in the datasheet before integration. | No |
Fieldbus Connection Via Separate Bus Coupler Indicates if the device supports fieldbus integration through an external bus coupler. Check this attribute when planning network architecture, as it affects wiring, configuration, and compatibility with your chosen fieldbus protocol. Verify against the datasheet for supported coupler models. | Yes |
Digital Outputs Configurable Check if the device allows you to configure its digital output channels, such as setting output type, polarity, or logic level. This is important for matching the module to your control system requirements. Verify the configuration options in the datasheet. | Yes |
Supply Voltage Type Specifies whether the device operates on alternating current (AC) or direct current (DC). This is critical for power supply design and compatibility. Verify the required voltage type against your application's power source and the component's datasheet to ensure proper operation. | DC |
Bluetooth Radio Standard Specifies the Bluetooth wireless standard supported, such as Classic or Low Energy. This affects data rate, range, and power consumption. Verify the Bluetooth version and profiles in the datasheet for your application. | No |
Supported PROFIBUS Protocols Specifies which PROFIBUS protocol variants are implemented, such as DP, PA, or FMS. Verify compatibility with your PLC and network configuration before integration. This attribute helps engineers select devices that match existing industrial communication infrastructure. | No |
Supply Voltage DC Specifies the direct current voltage required to power the component. Compare this value with your system's power rail to ensure compatibility. Always verify the operating range and absolute maximum ratings in the datasheet before design-in. | 19.2 - 19.2 |
Number Of Digital Outputs Specifies how many digital output channels the device provides. Compare this count with your system's control requirements to ensure sufficient I/O capacity. Verify against the datasheet for exact channel configuration and output type. | 3 |
IO-Link Master Support Indicates whether the device functions as an IO-Link master, enabling communication with IO-Link sensors and actuators. Verify this attribute when integrating the device into an industrial network, as it determines compatibility with IO-Link peripherals and the need for a separate master. | No |
UMTS Radio Standard Specifies support for the UMTS mobile communication standard. This determines network compatibility and data capabilities. Check the datasheet for supported frequency bands and carrier approvals to ensure proper operation. | No |
Supported INTERBUS-Safety Protocols Specifies which INTERBUS-Safety protocol variants are implemented in the device. Check this field to ensure compatibility with your safety network architecture and verify against the datasheet for exact protocol revisions. | No |
Supported Data-Highway Protocols Indicates which Data-Highway protocol versions are supported by the component. Use this attribute to confirm interoperability with existing industrial networks and always cross-reference the datasheet for protocol compliance details. | No |
Number Of USB Hardware Interfaces Indicates how many physical USB ports or controllers are integrated on the component. Compare this when selecting a microcontroller, interface bridge, or USB hub for your system. Verify against the datasheet to ensure it meets your connectivity requirements. | 0 |
Appendant Operation Agent (Ex Ib) Specifies if an extra operation agent is supported for Ex ib intrinsic safety applications. Verify this attribute when selecting components for hazardous area use, as it indicates enhanced functionality for certified equipment. | No |
Permitted Output Voltage Specifies the maximum voltage that can be safely applied to the output terminal without causing damage. Critical for power supplies, converters, and drivers. Always verify against the datasheet to ensure your application does not exceed this limit. | 20.4 - 264 |
ASI Protocol Support Indicates whether the device is equipped to communicate over the ASI interface. Check this attribute when selecting components for industrial automation networks that rely on ASI for sensor and actuator connectivity. Verify compatibility with your system's ASI master and cable infrastructure. | No |
Categories Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class. | Industrial Automation and Controls |
INTERBUS Protocol Support Indicates whether the device supports the INTERBUS fieldbus protocol for industrial communication. Use this attribute when integrating components into INTERBUS networks, ensuring seamless data exchange with PLCs and other devices. Confirm protocol version and network topology requirements from the datasheet. | No |
Switching Frequency Indicates the rate at which the power device toggles between on and off states. Higher frequencies allow smaller magnetics but increase switching losses. Verify this parameter against your application's requirements and the datasheet's recommended operating conditions. | 20 |
AS-Interface Safety At Work Protocol Support Indicates whether the device supports the AS-Interface Safety at Work protocol for functional safety communication. Verify this attribute when integrating safety-related sensors or actuators into a safety network. Check the datasheet for protocol version and certification details. | No |
MODBUS Protocol Support Indicates whether the device supports the MODBUS industrial communication protocol. Check this attribute to ensure compatibility with your control system or PLC network. Verify the supported MODBUS variants (RTU, ASCII, TCP) in the datasheet before integration. | No |
Supporting Protocol For Other Bus Systems Specifies if the component can communicate via additional bus protocols beyond its primary interface. Useful for engineers integrating mixed-protocol systems. Verify supported protocols in the datasheet to ensure compatibility with your microcontroller or host controller. | No |
Number Of RS-485 Interfaces Specifies the count of RS-485 hardware interfaces available on the device. This is critical for multi-drop industrial networks where multiple devices share a bus. Verify the number of ports against your system's communication requirements and ensure proper termination and addressing for reliable data transmission. | 0 |
Depth Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly. | 58 |
Digital Output Type Specifies the electrical configuration of the digital output, such as push-pull or open collector. This determines how the output drives external loads and its compatibility with your interface. Verify against the datasheet to ensure proper signal levels and logic. | Relay |
Sub-Categories Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application. | Controllers - PLC Modules |
Rail Mounting Specifies if the component can be installed on a standard DIN rail. This is critical for industrial control panels and automation systems. Verify the rail type and mounting dimensions against the datasheet to ensure proper fit and mechanical stability. | Yes |
EtherNet/IP Protocol Support Indicates whether the component supports EtherNet/IP for industrial automation networking. Verify this attribute against the datasheet to ensure compatibility with your control system and network infrastructure. | No |
LON Protocol Support Indicates whether the component supports LON (Local Operating Network) protocol for building automation and control. Check this attribute against the datasheet to confirm interoperability with your LON-based system. | No |
Mounting Type Specifies whether the component is designed for wall mounting or direct surface attachment. This affects installation requirements and mechanical stability. Verify the recommended mounting method and any necessary hardware against the datasheet to ensure proper fit and thermal performance. | No |
Number Of Digital Inputs Specifies the count of digital input channels on the device. Use this to verify that the component provides enough inputs for your control or sensing application. Always check the datasheet for input voltage levels and logic compatibility. | 0 |
Rack Mounting Indicates whether the component or equipment can be installed in a standard 19-inch rack. Buyers should verify this attribute when planning system integration or enclosure layout. Check the datasheet for mounting dimensions and hardware requirements. | No |
TCP/IP Protocol Support Specifies whether the component implements TCP/IP networking for data exchange over Ethernet or other interfaces. Engineers should verify this attribute when integrating the device into connected systems, ensuring compatibility with existing network infrastructure and firmware requirements. | No |
Number Of RS-232 Hardware Interfaces Indicates how many physical RS-232 ports are built into the component. Compare this when selecting microcontrollers, embedded modules, or communication boards. Verify against the datasheet to ensure sufficient serial connectivity for your application. | 0 |
CAN Protocol Support Specifies whether the component implements the CAN bus protocol for robust industrial communication. Engineers compare this to ensure compatibility with existing network architectures. Verify the exact protocol version and feature set in the datasheet before integration. | No |
Suitable For Safety Functions Indicates whether the component is certified or designed for use in safety-related applications. Verify this attribute against the datasheet and relevant safety standards before integrating the part into systems where failure could pose a risk. | No |
Terminal Form Describes the physical configuration of the component's leads or pads, such as through-hole, surface mount, or gull-wing. This affects PCB layout, soldering process, and mechanical fit. Confirm compatibility with your assembly method and footprint. | 3 - Relay |
System Accessory Indicates whether the item is an accessory intended for use with a larger system. This helps identify components that are not standalone but complement or extend the functionality of a main device. Verify compatibility with the target system before ordering. | Yes |
Short-Circuit Protection, Outputs Available Check this attribute to confirm that the device's output pins are safeguarded against short-circuit conditions. This protection prevents damage to the component and the system. Verify the specific implementation in the datasheet, as it may vary by output type. | No |
Wi-Fi Standard Choose the Wi-Fi protocol version supported by the module or device. This determines maximum data rate, frequency band, and compatibility with routers. Verify against the datasheet to ensure your network infrastructure and throughput requirements are met. | No |
Degree Of Protection (IP) Specifies the enclosure's resistance to dust and water ingress, crucial for industrial and outdoor electronics. Compare IP ratings to ensure the component suits your operating environment. Always verify the rating against the datasheet for exact conditions. | IP20 |
DeviceNet Safety Protocol Support Indicates whether the component implements the DeviceNet Safety protocol for functional safety communication. Verify this attribute against the datasheet when designing safety-critical systems, as it determines compatibility with safety controllers and proper integration into safety networks. | No |
Type Of Electric Connection Defines the method used for electrical connections, such as soldering, crimping, or plugging. This attribute is critical for ensuring the component fits your assembly process and mating connector. Always confirm the connection type with the datasheet and your PCB layout. | Plug-in connection |
Manufacturer Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts. | SIEMENS |
SUCONET Protocol Support Check this field to confirm that the device can communicate using the SUCONET protocol. This is important for integration with SUCONET-based control systems. Verify compatibility with your system's protocol version and ensure the device firmware supports it. | No |
Number Of RS-422 Hardware Interfaces Indicates how many independent RS-422 serial ports are built into the component. Compare this count with your system's required communication channels. Verify against the datasheet to ensure sufficient ports for your application without external expansion. | 0 |
Associated Apparatus (Ex Ia) Identifies the associated apparatus used in an intrinsic safety system with Ex ia protection. This component limits energy to hazardous areas. Verify compatibility with your barrier or isolator to ensure safe operation in explosive atmospheres. | No |
Frequency Operating frequency of the component, typically the clock or switching frequency. This determines the speed of operation and affects power dissipation and signal integrity. Verify the frequency range against your application's requirements and the datasheet specifications. | Siemens |
Dust Explosion Safety Category Indicates the equipment protection level for operation in dust atmospheres. Compare categories when selecting components for hazardous areas. Verify the category against the datasheet and relevant standards to ensure compliance with your installation requirements. | None |
With Optical Interface Select this attribute to indicate that the component includes an optical interface for data transmission or sensing. This is critical for fiber optic modules, transceivers, or sensors. Verify the interface type and compatibility with your system's optical specifications in the datasheet. | No |
SERCOS Protocol Support Indicates whether the device supports the SERCOS protocol for real-time motion control communication. Check this attribute to ensure compatibility with your automation network. Verify against the datasheet for supported protocol versions and profiles. | No |
DeviceNet Protocol Support Indicates whether the component supports DeviceNet, a common industrial network protocol. Check this attribute to ensure compatibility with your control system. Verify against the datasheet for specific protocol versions and features. | No |
Number Of Wireless Hardware Interfaces Indicates how many independent wireless interfaces are built into the component. Compare this when selecting modules for multi-radio designs. Verify against the datasheet to ensure the device supports the required number of simultaneous connections. | 0 |
GSM Standard Specifies the GSM generation and frequency bands supported by the module or device. Choose the standard that matches your network operator and regional coverage. Verify compatibility with your carrier's 2G, 3G, or 4G requirements before integration. | No |
Number Of Serial TTY Interfaces Indicates how many dedicated hardware serial TTY ports the component provides for asynchronous data communication. Compare this count with your system's required UART connections, and verify the exact interface type and pinout in the datasheet. | 0 |
For Use With/Related Products Specifies compatible or related products for this component. Use this to identify mating connectors, recommended drivers, or evaluation boards. Verify compatibility with your design and check the datasheet for any specific requirements. | SIMATIC ET 200SP |
Contact Voltage (DC) - Max Maximum DC voltage that can be safely applied across the contacts of a relay, switch, or connector. Exceeding this rating may cause arcing or insulation breakdown. Always verify this limit against the datasheet for your specific load conditions. | 73 |
| Parameter | Value |
|---|---|
Configuration Specifies the internal circuit topology or arrangement of the component, such as single, dual, or bridge configuration. This attribute helps engineers select the right part for their circuit design. Always verify the exact configuration against the datasheet to ensure compatibility with your application. | 24VDC |
Package Package type defines the physical dimensions, lead configuration, and mounting style of the component, such as SMD, through-hole, or BGA. It affects PCB layout, thermal performance, and assembly processes. Confirm the package matches your board design and manufacturing capabilities before ordering. | Bulk |
Notice documents
PCN / product notice documents
No public PCN / PDN records currently displayed
No public product notice document is currently displayed for 6ES71326HC500BU0. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.
Related sourcing options
Recommended products
Explore related Controllers - PLC Modules products to compare fit, stock status, datasheets, and sourcing options.
Common questions
Product FAQ
Targeted answers for buyers verifying the exact 6ES71326HC500BU0 ordering code, packaging, stock, datasheet, and replacement path.
What does 6ES71326HC500BU0 mean?
6ES71326HC500BU0 is the exact ordering code listed for a Controllers - PLC Modules component from Siemens. The current package reference is -, with listed context including -. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.
How should buyers verify the 6ES71326HC500BU0 ordering code?
Treat 6ES71326HC500BU0 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from Siemens, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.
What package is 6ES71326HC500BU0 supplied in?
6ES71326HC500BU0 is currently listed with package reference - from Siemens. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.
Is 6ES71326HC500BU0 currently available?
6ES71326HC500BU0 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (16793), available quantity (70647), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.
Where can I compare 6ES71326HC500BU0 alternatives?
A mapped alternative list is not currently published for 6ES71326HC500BU0. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.





