TrustCompo Website Logo | TrustCompo

G2R-14-DC5 Power Relays, Over 2 Amps by Omron

G2R-14-DC5 is a Power Relays, Over 2 Amps from Omron in manufacturer-listed packaging. It is commonly reviewed for RELAY GEN PURPOSE SPDT 8A 5V. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.

Pictures are for reference only. Please contact us for the latest pictures.

G2R-14-DC5 Power Relays, Over 2 Amps by Omron | TrustCompo
Pictures are for reference only. Please contact us for the latest pictures.
  • 365-Day GuaranteeAfter-sales support helps buyers handle quality questions with a clearer return and review window.
  • Ships within 24-48 HoursAvailable items can move quickly once the quote, quantity, and delivery details are confirmed.
  • 100% Anti-Counterfeit TestedParts are checked through authenticity-focused handling and inspection before shipment.

Key specifications

Part Number

G2R-14-DC5

Internal code

TCE000056465

Package

-

Manufacturer
Omron

Key specifications

Series

G2R

Min Quantity

1

Category
Relays
Description

RELAY GEN PURPOSE SPDT 8A 5V

key Attributes

-

Trust signals

Quality and trust signals

Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.

4 certifications
  • ISO 9001

    Quality management processes for more consistent sourcing and handling.

  • AS9120B

    Aerospace-focused distribution controls for traceability and reliability.

  • ISO 14001

    Environmental management discipline across warehouse and operating workflows.

  • ESD Control

    Electrostatic handling standards to help protect sensitive components.

RFQ checklist

Order process

Confirm the core buying details for G2R-14-DC5 before RFQ, PO release, and shipment planning.

  1. 1

    Confirm MPN

    Use the exact part number, manufacturer, package, and approval constraints in the RFQ.

  2. 2

    Check stock and price

    Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.

  3. 3

    Align documents

    Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.

  4. 4

    Arrange shipment

    Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.

Before PO release

Part confirmation

  • Exact MPN confirmed: G2R-14-DC5
  • Package to verify: -

Commercial confirmation

  • Live stock and lead time confirmed by RFQ
  • Final price and tax terms confirmed before PO release

Fulfillment & documents

  • Ship-from location: Hong Kong warehouse
  • Shipping method: DHL, FedEx, UPS, or buyer forwarder account

Technical parameters

Parameters

Compare grouped G2R-14-DC5 parameters from Omron, including package, series, key attributes, and technical values used for engineering and sourcing review.

  • Export Classifications & Environmental

    RoHS Status

    RoHS Compliant

  • Export Classifications & Environmental

    ECCN Code

    EAR99

  • Export Classifications & Environmental

    Moisture Sensitivity Level (MSL)

    Not Applicable

  • Product Parameter

    Power Consumption

    530mW

  • Product Attribute

    Part Status

    Active

  • Product Attribute

    Packaging

    Tray

G2R-14-DC5 Export Classifications & Environmental
ParameterValue
RoHS Status

Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.

RoHS Compliant
REACH SVHC

Indicates whether the product contains substances of very high concern as per the REACH regulation. Buyers should verify this for compliance with EU environmental standards, especially when exporting to Europe. Check the manufacturer's declaration or datasheet for accurate SVHC status.

Unknown
ECCN Code

Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.

EAR99
Moisture Sensitivity Level (MSL)

Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.

Not Applicable
G2R-14-DC5 Product Parameter
ParameterValue
Power Consumption

Typical power consumption of the component under normal operating conditions. This is important for power budget calculations and thermal management. Check the datasheet for maximum ratings and test conditions to ensure your design stays within safe limits.

530mW
G2R-14-DC5 Product Attribute
ParameterValue
Part Status

Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.

Active
Packaging

Indicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.

Tray
Mounting Type

Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.

Through Hole
Lead Free

Indicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.

Lead Free
Published

Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.

2002
Insulation Resistance

Indicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.

1000000000Ohm
Mounting Type

Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.

PCB, Through Hole
Factory Lead Time

Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.

24 Weeks
Depth

Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.

13.5mm
Current Rating

Specifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations.

10A
Relay Action

Specifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.

MOMENTARY
Termination

Describes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.

PC Pin
Coil/Input Supply Type

Specifies whether the coil or input circuit is designed for AC or DC supply. This determines the drive circuit compatibility and must match your control voltage. Verify the rated voltage and frequency against the datasheet to ensure proper operation.

DC
Dielectric Strength Between Open Contacts

Indicates the maximum voltage that can be applied across open contacts without causing an arc or breakdown. Critical for relay and switch isolation ratings. Verify against datasheet for safety margins in your application.

1000 Vrms
Input Switching Control Type

Specifies the method used to control input switching, such as AC, DC, or pulse. This determines how the device is triggered and affects compatibility with your control signal. Verify the required control type against your application's drive circuit and the datasheet specifications.

Random
Coil Type

Specifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.

Non Latching
Contact/Output Supply Type

Specifies whether the contact or output is powered by AC or DC. This determines the required control circuit and load compatibility. Verify against the datasheet to ensure correct polarity and voltage range for your application.

AC/DC
Electrical Life

Number of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.

100000 Cycle(s)
Release Time

Release time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.

5ms
Sub-Categories

Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.

Power Relays, Over 2 Amps
Seal Rating

Indicates the enclosure's protection level against gases, moisture, and contaminants. Compare ratings like IP or NEMA to ensure the component suits your operating environment. Verify the exact rating in the datasheet for reliable performance.

Sealed - Fully
Categories

Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.

Relays
Operating Temperature

Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.

-40°C~70°C
Coil Voltage

Specifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.

5VDC
Contact Form

Specifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.

SPDT (1 Form C)
Manufacturer

Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.

Omron
Must Operate Voltage

Defines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.

3.5VDC
Voltage - Rated AC

Maximum AC voltage that the component can safely withstand under specified conditions. This rating is critical for insulation and safety margins. Always compare it with the operating voltage in your circuit and derate according to the datasheet guidelines.

380V
Switching Voltage

Specifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.

380VAC 125VDC -Max
Series

Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.

G2R
Operate Time

Operate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.

15ms
Approval Agency

Indicates the certification body that has tested and approved the component for safety or regulatory compliance. Buyers should verify this matches their target market requirements, and engineers should check the datasheet for the specific standards and marks.

CE, CSA, UL, VDE
Reference Standard

Indicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.

CSA; SEMKO; TUV; UL; VDE
Contact Material

Specifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.

Silver Alloy
Weight

Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.

17g
Must Release Voltage

Specifies the voltage at which a relay is guaranteed to de-energize and return to its unoperated state. This value is critical for circuit design and ensuring reliable switching. Verify it against the datasheet to match your control signal and avoid unintended relay operation.

0.75VDC
Coil Current

Specifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.

106mA
Pb-Free Code

Indicates whether the component is lead-free per RoHS or other directives. Buyers use this to verify environmental compliance and avoid restricted substances. Always confirm with the datasheet or certificate of compliance.

yes
Number Of Pins

Total number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.

5
Number Of Terminations

Indicates the total number of electrical connection points on the component, such as pins or pads. This is critical for PCB footprint design and assembly. Verify it matches the package specification to ensure proper soldering and connectivity.

6
Termination Style

Indicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.

PC Pin
Relay Type

Classifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.

General Purpose
Coil Voltage (DC)

Specifies the nominal DC voltage required to energize the relay coil. Verify this matches your control circuit supply to ensure reliable switching. Check the datasheet for allowable tolerance and minimum pickup voltage.

5V
Throw Configuration

Specifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.

SPDT
Max Voltage Rating (DC)

Specifies the maximum continuous direct current voltage the component can safely withstand. Engineers compare this rating to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet for derating guidelines and environmental conditions.

125V
Max Current Rating

Specifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits.

10A
Width

Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.

13.5mm
Contact (DC) Max Rating R Load

Specifies the maximum DC current and voltage that the contact can safely switch when driving a purely resistive load. This rating is critical for relay and switch selection. Always verify against the datasheet because inductive or capacitive loads require derating.

10A@30VDC
Coil Resistance

Specifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.

47Ohm
Max Voltage Rating (AC)

Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.

380V
Power Rating

Specifies the maximum power the component can safely dissipate under defined operating conditions. Compare this value with your circuit's power requirements to prevent overheating and ensure reliable operation. Always verify against the datasheet for derating curves and ambient temperature limits.

530mW
Height

Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.

25.5mm
Coil Power

Power consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.

530mW
Length

Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.

29mm
Relay Form

Specifies the contact arrangement of the relay, such as SPST, SPDT, or DPDT. This determines how many circuits the relay can switch and in what configuration. Verify the form against your application requirements to ensure proper switching functionality.

1 FORM A
Contact Current Rating

Specifies the maximum continuous current each contact can safely carry. Compare this rating with your application's load requirements to prevent overheating or contact degradation. Always verify against the datasheet for derating curves and ambient temperature conditions.

8A
Body Breadth

Measure the widest dimension of the component body, excluding leads and terminals. This attribute helps determine PCB footprint compatibility and mechanical fit. Verify against the datasheet drawing for accurate placement and clearance in your assembly.

13 mm
Manufacturer'S Part No.

The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.

G2R-14-DC5

Datasheet preview

Datasheet PDF viewer

Preview the G2R-14-DC5 datasheet from Omron to check package, electrical characteristics, application notes, and document evidence before RFQ.

Omron

G2R-14-DC5

Page 1 of 0
/ —
Search within the PDF viewer.Try
Loading PDF viewer...

Notice documents

PCN / product notice documents

0 documents

No public PCN / PDN records currently displayed

No public product notice document is currently displayed for G2R-14-DC5. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.

Common questions

Product FAQ

Targeted answers for buyers verifying the exact G2R-14-DC5 ordering code, packaging, stock, datasheet, and replacement path.

What does G2R-14-DC5 mean?

G2R-14-DC5 is the exact ordering code listed for a Power Relays, Over 2 Amps component from Omron. The current package reference is -, with listed context including RELAY GEN PURPOSE SPDT 8A 5V. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.

How should buyers verify the G2R-14-DC5 ordering code?

Treat G2R-14-DC5 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from Omron, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.

What package is G2R-14-DC5 supplied in?

G2R-14-DC5 is currently listed with package reference - from Omron. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.

Is G2R-14-DC5 currently available?

G2R-14-DC5 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (109716), available quantity (84616), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.

Where can I compare G2R-14-DC5 alternatives?

A mapped alternative list is not currently published for G2R-14-DC5. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.