G2R-2-DC12 is a Power Relays, Over 2 Amps from Omron in manufacturer-listed packaging. It is commonly reviewed for RELAY GEN PURPOSE DPDT 5A 12V. This page lists current TrustCompo stock, tier pricing, package data, datasheet access, compliance attributes, Hong Kong warehouse shipping options, payment confirmation, and RFQ options for buyers verifying this exact ordering code.
Review TrustCompo quality credentials, traceability support, anti-counterfeit handling, and inspection controls before sending an RFQ.
4 certifications
ISO 9001
Quality management processes for more consistent sourcing and handling.
AS9120B
Aerospace-focused distribution controls for traceability and reliability.
ISO 14001
Environmental management discipline across warehouse and operating workflows.
ESD Control
Electrostatic handling standards to help protect sensitive components.
RFQ checklist
Order process
Confirm the core buying details for G2R-2-DC12 before RFQ, PO release, and shipment planning.
1
Confirm MPN
Use the exact part number, manufacturer, package, and approval constraints in the RFQ.
2
Check stock and price
Verify live availability, MOQ, lead time, final unit price, and tax terms before PO release.
3
Align documents
Confirm datasheet, CoC, traceability, lifecycle notes, and inspection scope when required.
4
Arrange shipment
Release the PO and align DHL, FedEx, UPS, or buyer forwarder shipment from Hong Kong.
Before PO release
Part confirmation
Exact MPN confirmed: G2R-2-DC12
Package to verify: -
Commercial confirmation
Live stock and lead time confirmed by RFQ
Final price and tax terms confirmed before PO release
Fulfillment & documents
Ship-from location: Hong Kong warehouse
Shipping method: DHL, FedEx, UPS, or buyer forwarder account
Product overview
Product overview
Review the sourcing context for G2R-2-DC12 from Omron, including product identity, application fit, package notes, and purchasing considerations.
The G2R-2-DC12 is a relay manufactured by Omron, a well-known company in the field of automation and control equipment. This particular relay is part of the G2R series, which is recognized for its reliability and versatility in various applications.
Physical Characteristics:
Form Factor: The G2R-2-DC12 is a compact, rectangular relay designed for easy integration into control panels and automation systems. It typically features a standard footprint that allows for straightforward mounting on DIN rails or in sockets.
Dimensions: While specific dimensions can vary slightly, it generally measures around 29 mm in width, 28 mm in height, and 19 mm in depth, making it suitable for space-constrained environments.
Terminals: The relay is equipped with multiple terminals for easy wiring. These terminals are designed to accommodate standard gauge wires, ensuring secure connections.
Electrical Specifications:
Coil Voltage: The "DC12" in its name indicates that the relay operates on a 12V DC coil voltage. This makes it suitable for low-voltage applications, commonly found in control circuits and automation systems.
Contact Configuration: The G2R-2-DC12 features a double-pole, double-throw (DPDT) contact configuration. This allows it to control two separate circuits simultaneously, providing flexibility in its applications.
Contact Rating: The relay is rated for a maximum switching current of around 10A and a maximum switching voltage of 250V AC or 30V DC, making it capable of handling a variety of loads.
Performance Characteristics:
Operating Temperature: The relay is designed to operate effectively within a temperature range of -40°C to +70°C, ensuring reliability in diverse environmental conditions.
Mechanical Life: The G2R-2-DC12 boasts a mechanical life of approximately 10 million operations, indicating its durability and long service life.
Electrical Life: The electrical life is rated for around 100,000 operations at rated load, which is a testament to its robustness in frequent switching applications.
Applications:
The G2R-2-DC12 relay is widely used in various applications, including:
Industrial Automation: It is commonly employed in control panels, machinery, and process automation systems.
Home Automation: The relay can be used in smart home systems for controlling lights, motors, and other devices.
HVAC Systems: It is often utilized in heating, ventilation, and air conditioning systems for controlling fans and compressors.
Additional Features:
LED Indicator: Some versions of the G2R-2-DC12 may include an LED indicator that provides visual feedback on the relay's status, enhancing usability during troubleshooting and maintenance.
Safety Standards: The relay complies with various international safety standards, ensuring it meets the necessary requirements for use in commercial and industrial applications.
In summary, the Omron G2R-2-DC12 relay is a versatile and reliable component suitable for a wide range of applications, characterized by its compact design, robust electrical specifications, and long operational life.
Technical parameters
Parameters
Compare grouped G2R-2-DC12 parameters from Omron, including package, series, key attributes, and technical values used for engineering and sourcing review.
Product Attribute
Part Status
Active
Product Attribute
Packaging
Tray
Product Attribute
Mounting Type
Through Hole
Product Attribute
Current Rating
5A
Product Attribute
Voltage - Rated AC
250V
Product Attribute
Lead Free
Lead Free
G2R-2-DC12 Product Attribute
Parameter
Value
Part Status
Lifecycle status of the part, such as active or obsolete. Indicates availability and long-term support from the manufacturer. Check this before design-in to avoid last-time buys or supply disruptions. Verify with the datasheet or distributor for current status.
Active
Packaging
Indicates the form of delivery for the component, such as tape and reel, tube, or tray. This affects handling, storage, and assembly processes. Verify the packaging type matches your production requirements and equipment compatibility.
Tray
Mounting Type
Specifies how the component is attached to the PCB, such as through-hole or surface mount. This affects assembly processes, thermal performance, and mechanical strength. Buyers should verify compatibility with their manufacturing capabilities and design requirements.
Through Hole
Current Rating
Specifies the maximum continuous current the component can safely carry under specified conditions. Compare this value with your circuit's expected load to ensure reliable operation. Always verify against the datasheet for temperature derating and mounting considerations.
5A
Voltage - Rated AC
Maximum AC voltage that the component can safely withstand under specified conditions. This rating is critical for insulation and safety margins. Always compare it with the operating voltage in your circuit and derate according to the datasheet guidelines.
250V
Lead Free
Indicates whether the component is manufactured without lead, complying with RoHS and similar regulations. Check this attribute to ensure environmental compliance for your market. Verify against the datasheet for exact material declarations.
Lead Free
Width
Physical width of the component body, typically in millimeters. Essential for PCB footprint design and mechanical fit. Verify against the datasheet to ensure proper clearance and compatibility with your board layout and enclosure.
13mm
Published
Published indicates the date when the product data was released or updated in the catalog. It helps buyers assess the freshness of the information and whether the component is current or possibly obsolete. Check the datasheet for the latest revisions.
2002
Insulation Resistance
Indicates the resistance between insulated conductors or contacts, typically measured in megohms. High values ensure minimal leakage current and safe operation. Check datasheet for minimum acceptable levels under specified test conditions.
1000000000Ohm
Mounting Type
Specifies how the component attaches to the PCB or assembly, such as surface mount, through-hole, or chassis mount. This affects soldering process, mechanical stability, and thermal performance. Verify compatibility with your board layout and assembly capabilities.
PCB, Through Hole
Factory Lead Time
Indicates the typical duration from order confirmation to shipment from the manufacturer's facility. This helps you plan production schedules and inventory. Verify current lead times with your distributor or supplier, as they may vary based on order quantity, product availability, and market conditions.
18 Weeks
Relay Action
Specifies the switching behavior of the relay, such as latching or non-latching. This determines how the relay responds to control signals and whether it maintains its state after power is removed. Verify against the datasheet for proper circuit design.
MOMENTARY
Termination
Describes the method used to connect the component to the circuit board, such as solder, press-fit, or wire wrap. This affects assembly processes, reliability, and repairability. Check the termination type against your PCB footprint and soldering process to ensure compatibility.
PC Pin
Dielectric Strength Between Open Contacts
Indicates the maximum voltage that can be applied across open contacts without causing an arc or breakdown. Critical for relay and switch isolation ratings. Verify against datasheet for safety margins in your application.
1000 Vrms
Coil Type
Specifies the coil's operational mode, such as latching or non-latching. This determines how the relay or solenoid maintains its state after power is removed. Verify the coil type against your circuit requirements to ensure proper latching behavior and power consumption.
Non Latching
Coil Voltage
Specifies the nominal voltage required to energize the relay coil. Verify this matches your control circuit voltage to ensure reliable switching. Check the datasheet for tolerance and minimum pickup voltage.
12VDC
Electrical Life
Number of switching operations under rated load before failure. Compare across relays, switches, and connectors to ensure longevity in your application. Verify against datasheet for specific load conditions and expected endurance.
100000 Cycle(s)
Release Time
Release time is the interval from removing coil power until contacts fully open. It affects switching speed and sequencing in control circuits. Verify against datasheet for relay or contactor applications where timing is critical.
5ms
Sub-Categories
Indicates the specific product subcategories or classifications within the broader component family. Helps narrow down search results and identify the exact type of component needed for your design. Review the subcategory to ensure compatibility with your application.
Power Relays, Over 2 Amps
Categories
Lists the product categories or classifications assigned to this component, such as connectors, capacitors, or modules. This helps in filtering and comparing similar parts. Review the categories to ensure the component fits your application and to find alternative parts in the same class.
Relays
Contact Form
Specifies the electrical configuration of the contact set, such as SPST or DPDT. This determines how many circuits the switch or relay can control and in what arrangement. Verify the exact form against the datasheet to ensure it matches your application's switching requirements.
DPDT (2 Form C)
Contact Resistance
Contact resistance measures the electrical resistance at the interface between mating contacts. Lower values indicate better conductivity and less heat generation. Compare this parameter across connectors, relays, and switches to ensure reliable signal integrity and power transfer. Always verify against the datasheet for your specific application.
50mOhm
Throw Configuration
Specifies the number of output positions per pole in a switch, such as SPST or DPDT. This determines the switching logic and circuit routing. Verify against the datasheet to ensure the switch matches your application's required contact arrangement and signal path.
DPDT
Operating Temperature
Specifies the ambient temperature range within which the component reliably functions. Compare this with your application's thermal environment to ensure proper operation. Always verify against the datasheet for derating curves and maximum ratings.
-40°C~70°C
Type
Select the component category that best matches your application, such as resistor, capacitor, diode, or connector. This classification helps narrow down the correct part family and ensures compatibility with your circuit design. Verify the type against the datasheet to avoid mismatches.
Electromechanical
Must Operate Voltage
Defines the minimum voltage at which the device is guaranteed to operate, such as a relay pickup voltage or a comparator threshold. This ensures reliable activation under specified conditions. Verify that your supply voltage exceeds this level to guarantee proper operation.
8.4VDC
Manufacturer
Identifies the company that designed and produced the component. Buyers often filter by manufacturer to ensure brand reliability, quality standards, and supply chain consistency. Verify the manufacturer against the datasheet and official packaging to avoid counterfeit parts.
Omron
Dielectric Strength Between Coil And Contacts
This is the maximum voltage that can be applied between the relay coil and its contacts without causing insulation breakdown. It ensures safe isolation between control and switching circuits. Verify this rating against the datasheet for your application's voltage requirements.
5000 Vrms
Seal Rating
Indicates the enclosure's protection level against gases, moisture, and contaminants. Compare ratings like IP or NEMA to ensure the component suits your operating environment. Verify the exact rating in the datasheet for reliable performance.
Sealed - Flux Protection
Switching Voltage
Specifies the maximum voltage that the contact can safely switch during operation. Essential for ensuring the component matches your circuit's voltage levels. Always check the datasheet for derating factors and load type.
380VAC 125VDC -Max
Series
Indicates the product series or family, grouping components with similar design and specifications. Helps identify compatible parts and compare within a product line. Verify the series against the datasheet to ensure correct application.
G2R
Operate Time
Operate time is the interval from applying power to the coil until the contacts fully close. It is critical for timing-sensitive circuits and relay sequencing. Verify this value in the datasheet to ensure your application meets switching speed requirements.
15ms
Approval Agency
Indicates the certification body that has tested and approved the component for safety or regulatory compliance. Buyers should verify this matches their target market requirements, and engineers should check the datasheet for the specific standards and marks.
CE, CSA, UL, VDE
Reference Standard
Indicates the industry specification or standard the component complies with, such as IEC, MIL, or JEDEC. Buyers use this to ensure regulatory and quality compliance. Verify the exact standard and revision against the datasheet before design-in.
CSA; SEMKO; TUV; UL; VDE
Contact Material
Specifies the metal alloy used for the electrical contact surfaces, affecting conductivity, wear resistance, and corrosion behavior. Compare materials like silver, gold, or palladium for signal integrity and durability. Verify against datasheet for application-specific requirements.
Silver Alloy
Relay Form
Specifies the contact arrangement of the relay, such as SPST, SPDT, or DPDT. This determines how many circuits the relay can switch and in what configuration. Verify the form against your application requirements to ensure proper switching functionality.
1 FORM C
Weight
Specifies the physical weight of the electronic component, important for logistics, shipping cost, and mechanical design. Verify the exact weight in the datasheet or packaging information, as it may vary with packaging type and quantity.
17g
Radiation Hardening
Indicates if the component is designed to withstand ionizing radiation in space, nuclear, or high-energy physics applications. Compare radiation-tolerant vs. radiation-hardened parts for mission-critical designs. Verify the total ionizing dose (TID) and single-event effect (SEE) ratings in the datasheet.
No
Pb-Free Code
Indicates whether the component is lead-free per RoHS or other directives. Buyers use this to verify environmental compliance and avoid restricted substances. Always confirm with the datasheet or certificate of compliance.
yes
Number Of Terminations
Indicates the total number of electrical connection points on the component, such as pins or pads. This is critical for PCB footprint design and assembly. Verify it matches the package specification to ensure proper soldering and connectivity.
6
Number Of Pins
Total number of pins or contacts on the component. This determines the footprint and mating connector requirements. Always match the pin count to your PCB layout and connector specification to ensure proper electrical and mechanical connection.
8
Termination Style
Indicates how the component connects to the PCB, such as through-hole, SMD, or press-fit. This affects assembly method, thermal performance, and mechanical strength. Verify compatibility with your board design and soldering process before ordering.
PC Pin
Relay Type
Classifies the relay by construction or application, such as electromechanical, solid state, or latching. Helps select the right relay for your switching needs. Refer to the datasheet for specific characteristics and ratings.
General Purpose
Coil Voltage (DC)
Specifies the nominal DC voltage required to energize the relay coil. Verify this matches your control circuit supply to ensure reliable switching. Check the datasheet for allowable tolerance and minimum pickup voltage.
12V
Max Voltage Rating (DC)
Specifies the maximum continuous direct current voltage the component can safely withstand. Engineers compare this rating to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet for derating guidelines and environmental conditions.
125V
Number Of Contacts
Total number of electrical contacts in the connector, which determines the maximum number of circuits that can be connected. This is a critical parameter for matching the connector to your wire harness requirements. Ensure the contact count aligns with your signal and power needs.
2
Contact Current (AC) - Max
Specifies the highest alternating current the contacts can safely carry under normal operating conditions. Compare this value with your circuit's expected AC load to ensure reliable switching and avoid overheating. Always verify against the datasheet for derating factors and temperature limits.
5A
Contact Current (DC) Max
Specifies the highest continuous direct current the contact can safely carry without overheating or degrading. Compare this rating with your circuit's expected load, and verify it against the datasheet for derating curves and ambient temperature conditions.
5A
Voltage - Rated DC
Specifies the maximum DC voltage the component can safely handle under rated conditions. Engineers compare this to the circuit's operating voltage to ensure adequate margin. Always verify against the datasheet's derating curves for temperature and reliability.
30V
Max Current Rating
Specifies the highest continuous current the component can safely carry under specified conditions. Compare this rating with your circuit's expected load to prevent overheating or failure. Always verify against the datasheet's derating curves and ambient temperature limits.
5A
Max Voltage Rating (AC)
Specifies the highest alternating current voltage the component can withstand continuously without damage. Compare this rating with your circuit's operating voltage and transients. Always verify against the datasheet for derating factors and safety margins.
380V
Contact (DC) Max Rating R Load
Specifies the maximum DC current and voltage that the contact can safely switch when driving a purely resistive load. This rating is critical for relay and switch selection. Always verify against the datasheet because inductive or capacitive loads require derating.
5A@30VDC
Switching Current
Specifies the maximum current that a switch, relay, or connector can safely make or break during operation. Compare this rating with your load current to avoid contact welding or arcing. Always verify against the datasheet for resistive and inductive loads.
5A
Ambient Temperature Range High
Defines the upper limit of ambient temperature for reliable operation without thermal damage or performance degradation. Ensure your system's cooling keeps the component below this threshold. Check the datasheet for derating curves and thermal resistance values.
70°C
Manufacturer'S Part No.
The unique part number assigned by the original component manufacturer. Use this to cross-reference datasheets, verify specifications, and ensure the exact component matches your design requirements. Always confirm the number against the manufacturer's official documentation.
G2R-2-DC12
Power Rating
Specifies the maximum power the component can safely dissipate under defined operating conditions. Compare this value with your circuit's power requirements to prevent overheating and ensure reliable operation. Always verify against the datasheet for derating curves and ambient temperature limits.
530mW
Must Release Voltage
Specifies the voltage at which a relay is guaranteed to de-energize and return to its unoperated state. This value is critical for circuit design and ensuring reliable switching. Verify it against the datasheet to match your control signal and avoid unintended relay operation.
1.8VDC
Coil Current
Specifies the current drawn by the relay or solenoid coil at its nominal voltage. This value is critical for driver circuit design and power supply sizing. Verify against the datasheet to ensure compatibility with your control circuitry and avoid overloading.
43.6mA
Height
Physical height of the component, measured from the mounting surface to the topmost point. This dimension is critical for clearance in compact assemblies and for ensuring proper fit within enclosures. Always verify against the datasheet for tolerance and mounting considerations.
25.5mm
Coil Resistance
Specifies the DC resistance of the relay coil, which determines the current draw and power consumption at the rated voltage. Engineers compare this value to ensure the relay driver circuit can supply sufficient current and to calculate coil power dissipation. Verify against the datasheet for proper operation.
275Ohm
Coil Power
Power consumed by the relay coil when energized at its nominal voltage. Compare this value to ensure the coil's heat dissipation is within the relay's thermal limits. Verify against the datasheet for your specific coil voltage and operating conditions.
530mW
Length
Specifies the physical length of the component body, typically in millimeters. This dimension is critical for PCB layout and mechanical fit. Verify against the datasheet to ensure proper clearance and alignment in your design.
29mm
Depth
Physical depth of the component body, measured in millimeters or inches. This dimension affects PCB layout and mechanical fit. Verify against the datasheet for proper clearance in your enclosure or assembly.
13mm
G2R-2-DC12 Product Parameter
Parameter
Value
Power Consumption
Typical power consumption of the component under normal operating conditions. This is important for power budget calculations and thermal management. Check the datasheet for maximum ratings and test conditions to ensure your design stays within safe limits.
530mW
G2R-2-DC12 Export Classifications & Environmental
Parameter
Value
RoHS Status
Indicates whether the component complies with the EU RoHS directive restricting hazardous substances. Buyers should verify this status for regulatory compliance and market access. Check the datasheet or certificate for exact compliance details.
RoHS Compliant
ECCN Code
Export Control Classification Number assigned by the U.S. Commerce Department. It determines export licensing requirements for electronic components. Verify the ECCN against the manufacturer's datasheet or export compliance documentation before shipping internationally.
EAR99
Moisture Sensitivity Level (MSL)
Indicates the floor life of a component before it must be baked prior to soldering. Higher levels require stricter handling and shorter exposure times. Verify the MSL rating in the datasheet to ensure proper storage and assembly conditions.
Not Applicable
Datasheet preview
Datasheet PDF viewer
Preview the G2R-2-DC12 datasheet from Omron to check package, electrical characteristics, application notes, and document evidence before RFQ.
No public product notice document is currently displayed for G2R-2-DC12. Confirm PCN, PDN, EOL, date code, and lifecycle status during RFQ before production purchase.
Related sourcing options
Recommended products
Explore related Power Relays, Over 2 Amps products to compare fit, stock status, datasheets, and sourcing options.
Targeted answers for buyers verifying the exact G2R-2-DC12 ordering code, packaging, stock, datasheet, and replacement path.
What does G2R-2-DC12 mean?
G2R-2-DC12 is the exact ordering code listed for a Power Relays, Over 2 Amps component from Omron. The current package reference is -, with listed context including RELAY GEN PURPOSE DPDT 5A 12V. Buyers should use the full code when requesting stock, price, datasheet, or compliance confirmation.
How should buyers verify the G2R-2-DC12 ordering code?
Treat G2R-2-DC12 as the full ordering code during RFQ and engineering review. Confirm the listed - package, manufacturer documentation from Omron, datasheet ordering table, reel or packing details, and any customer approval constraints before substitution or PO release.
What package is G2R-2-DC12 supplied in?
G2R-2-DC12 is currently listed with package reference - from Omron. Buyers should confirm the manufacturer package drawing, footprint, pinout, tape-and-reel details, and receiving requirements before approval.
Is G2R-2-DC12 currently available?
G2R-2-DC12 is currently marked with stock availability on this page. Before ordering, confirm the package (-), listed stock (73883), available quantity (71691), required quantity, lead time, final price, compliance needs, and exact ordering code match through RFQ.
Where can I compare G2R-2-DC12 alternatives?
A mapped alternative list is not currently published for G2R-2-DC12. Send an RFQ with the target quantity, package constraints, and approval requirements so TrustCompo can help review credible replacement options.